• ورود به سامانه
      مشاهده مورد 
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Analytical and Bioanalytical Chemistry Research
      • Volume 7, Issue 4
      • مشاهده مورد
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Analytical and Bioanalytical Chemistry Research
      • Volume 7, Issue 4
      • مشاهده مورد
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      Development of AgNPs-tragacanth Conjugated Gel as a Novel Green Membrane in Electro-membrane Extraction: Tenofovir Disoproxil Fumarate Assay in Human Plasma Samples

      (ندگان)پدیدآور
      Hajizadeh, SalahaddinFarhadi, Khalil
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      1.223 مگابایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Research Paper
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      AgNPs-Tragacanth conjugate gel as an eco friendly and low cost membrane was applied for the effective electromembrane extraction (EME) of Tenofovir disproxil fumarate, an important acidic and high polar (log p=1.25) antiviral drug, followed by HPLC-UV determination. The effect of various parameters on the extraction efficiency including the presence of AgNPs, tragacanth gum concentration, gel thickness, pH values of the donor and acceptor phases, applied voltage, extraction time and agitation rate were investigated and optimized. The best extraction efficiency was obtained with: 2.5% w/v of tragacanth gum, 4.0 mm gel thickness, donor phase pH = 7.0, acceptor phase pH = 8.0, applied voltage: 30 V, extraction time: 15 min and agitation rate: 500 rpm. During method validation under the optimized conditions good linearity dynamic range (LDR) between 10-750 ngmL-1 with coefficient of determination (R2) =0.999 was obtained. Limit of detection (LOD) and Limit of quantitation (LOQ) were estimated to be 5.55 ng mL-1 and 10 ng mL-1, respectively. According to the validation results, the RSD values for intra and inter-day precisions were in the range of 0.53 to 10.04% and the relative error (RE %) ranged between -2.31 to 8.20% Finally the applicability of this method in real samples was confirmed by an acceptable performance in extraction and determination of TDF in human plasma samples.
      کلید واژگان
      Electro-membrane extraction
      AgNPs-Tragacanth
      Green method
      Tenofovir disproxil fumarate
      HPLC-UV

      شماره نشریه
      4
      تاریخ نشر
      2020-11-01
      1399-08-11
      ناشر
      Iranian Chemical Society
      سازمان پدید آورنده
      Department of Analytical Chemistry, Faculty of Chemistry, Urmia University, Urmia, Iran
      Department of Analytical Chemistry, Faculty of Chemistry, Urmia University, Urmia, Iran

      شاپا
      2383-093X
      URI
      https://dx.doi.org/10.22036/abcr.2020.210593.1439
      http://www.analchemres.org/article_107259.html
      https://iranjournals.nlai.ir/handle/123456789/99436

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب