• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Analytical and Bioanalytical Chemistry Research
    • Volume 7, Issue 4
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Analytical and Bioanalytical Chemistry Research
    • Volume 7, Issue 4
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Development of AgNPs-tragacanth Conjugated Gel as a Novel Green Membrane in Electro-membrane Extraction: Tenofovir Disoproxil Fumarate Assay in Human Plasma Samples

    (ندگان)پدیدآور
    Hajizadeh, SalahaddinFarhadi, Khalil
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.223 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Research Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    AgNPs-Tragacanth conjugate gel as an eco friendly and low cost membrane was applied for the effective electromembrane extraction (EME) of Tenofovir disproxil fumarate, an important acidic and high polar (log p=1.25) antiviral drug, followed by HPLC-UV determination. The effect of various parameters on the extraction efficiency including the presence of AgNPs, tragacanth gum concentration, gel thickness, pH values of the donor and acceptor phases, applied voltage, extraction time and agitation rate were investigated and optimized. The best extraction efficiency was obtained with: 2.5% w/v of tragacanth gum, 4.0 mm gel thickness, donor phase pH = 7.0, acceptor phase pH = 8.0, applied voltage: 30 V, extraction time: 15 min and agitation rate: 500 rpm. During method validation under the optimized conditions good linearity dynamic range (LDR) between 10-750 ngmL-1 with coefficient of determination (R2) =0.999 was obtained. Limit of detection (LOD) and Limit of quantitation (LOQ) were estimated to be 5.55 ng mL-1 and 10 ng mL-1, respectively. According to the validation results, the RSD values for intra and inter-day precisions were in the range of 0.53 to 10.04% and the relative error (RE %) ranged between -2.31 to 8.20% Finally the applicability of this method in real samples was confirmed by an acceptable performance in extraction and determination of TDF in human plasma samples.
    کلید واژگان
    Electro-membrane extraction
    AgNPs-Tragacanth
    Green method
    Tenofovir disproxil fumarate
    HPLC-UV

    شماره نشریه
    4
    تاریخ نشر
    2020-11-01
    1399-08-11
    ناشر
    Iranian Chemical Society
    سازمان پدید آورنده
    Department of Analytical Chemistry, Faculty of Chemistry, Urmia University, Urmia, Iran
    Department of Analytical Chemistry, Faculty of Chemistry, Urmia University, Urmia, Iran

    شاپا
    2383-093X
    URI
    https://dx.doi.org/10.22036/abcr.2020.210593.1439
    http://www.analchemres.org/article_107259.html
    https://iranjournals.nlai.ir/handle/123456789/99436

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب