نمایش مختصر رکورد

dc.contributor.authorHajizadeh, Salahaddinen_US
dc.contributor.authorFarhadi, Khalilen_US
dc.date.accessioned1399-07-08T20:56:32Zfa_IR
dc.date.accessioned2020-09-29T20:56:32Z
dc.date.available1399-07-08T20:56:32Zfa_IR
dc.date.available2020-09-29T20:56:32Z
dc.date.issued2020-11-01en_US
dc.date.issued1399-08-11fa_IR
dc.date.submitted2019-12-15en_US
dc.date.submitted1398-09-24fa_IR
dc.identifier.citationHajizadeh, Salahaddin, Farhadi, Khalil. (2020). Development of AgNPs-tragacanth Conjugated Gel as a Novel Green Membrane in Electro-membrane Extraction: Tenofovir Disoproxil Fumarate Assay in Human Plasma Samples. Analytical and Bioanalytical Chemistry Research, 7(4), 415-429. doi: 10.22036/abcr.2020.210593.1439en_US
dc.identifier.issn2383-093X
dc.identifier.urihttps://dx.doi.org/10.22036/abcr.2020.210593.1439
dc.identifier.urihttp://www.analchemres.org/article_107259.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/99436
dc.description.abstractAgNPs-Tragacanth conjugate gel as an eco friendly and low cost membrane was applied for the effective electromembrane extraction (EME) of Tenofovir disproxil fumarate, an important acidic and high polar (log p=1.25) antiviral drug, followed by HPLC-UV determination. The effect of various parameters on the extraction efficiency including the presence of AgNPs, tragacanth gum concentration, gel thickness, pH values of the donor and acceptor phases, applied voltage, extraction time and agitation rate were investigated and optimized. The best extraction efficiency was obtained with: 2.5% w/v of tragacanth gum, 4.0 mm gel thickness, donor phase pH = 7.0, acceptor phase pH = 8.0, applied voltage: 30 V, extraction time: 15 min and agitation rate: 500 rpm. During method validation under the optimized conditions good linearity dynamic range (LDR) between 10-750 ngmL-1 with coefficient of determination (R2) =0.999 was obtained. Limit of detection (LOD) and Limit of quantitation (LOQ) were estimated to be 5.55 ng mL-1 and 10 ng mL-1, respectively. According to the validation results, the RSD values for intra and inter-day precisions were in the range of 0.53 to 10.04% and the relative error (RE %) ranged between -2.31 to 8.20% Finally the applicability of this method in real samples was confirmed by an acceptable performance in extraction and determination of TDF in human plasma samples.en_US
dc.format.extent1252
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherIranian Chemical Societyen_US
dc.relation.ispartofAnalytical and Bioanalytical Chemistry Researchen_US
dc.relation.isversionofhttps://dx.doi.org/10.22036/abcr.2020.210593.1439
dc.subjectElectro-membrane extractionen_US
dc.subjectAgNPs-Tragacanthen_US
dc.subjectGreen methoden_US
dc.subjectTenofovir disproxil fumarateen_US
dc.subjectHPLC-UVen_US
dc.titleDevelopment of AgNPs-tragacanth Conjugated Gel as a Novel Green Membrane in Electro-membrane Extraction: Tenofovir Disoproxil Fumarate Assay in Human Plasma Samplesen_US
dc.typeTexten_US
dc.typeResearch Paperen_US
dc.contributor.departmentDepartment of Analytical Chemistry, Faculty of Chemistry, Urmia University, Urmia, Iranen_US
dc.contributor.departmentDepartment of Analytical Chemistry, Faculty of Chemistry, Urmia University, Urmia, Iranen_US
dc.citation.volume7
dc.citation.issue4
dc.citation.spage415
dc.citation.epage429
nlai.contributor.orcid0000-0002-0487-6099


فایل‌های این مورد

Thumbnail

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد