    Stochastic Comparisons of Probability Distribution Functions with Experimental Data in a Liquid-Liquid Extraction Column for Determination of Drop Size Distributions

    (ندگان)پدیدآور
    Houshyar, Sh.Torab-Mostaedi, M.Moosavian, S. M. A.Mousavi, Seyed HamedAsadollahzadeh, M.
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    366.5کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Full article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    The droplet size distribution in the column is usually represented as the average volume to surface area, known as the Sauter mean drop diameter. It is a key variable in the extraction column design. A study of the drop size distribution and Sauter-mean drop diameter for a liquid-liquid extraction column has been presented for a range of operating conditions and three different liquid-liquid systems. The effects of rotor speed, and dispersed and continuous phase velocities on drop size are investigated. Drop size distribution are appropriately described using the normal and log-normal probability density functions. The mathematical approach is used to determine the constant parameters in these functions and to provide the fit of the experimental data with them. and empirical expressions are derived to predict the parameters of the distribution curve as a function of operating variables, and physical properties of the systems. Good agreement between the prediction and experiments was achieved for all investigated operating conditions. An empirical correlation is also proposed to predict the Sauter-mean drop diameter with mean deviation of 9.8%.
    کلید واژگان
    Liquid-liquid extraction column
    Sauter-mean drop diameter
    drop size distribution
    liquid-liquid extraction
    Separation Technology,

    شماره نشریه
    3
    تاریخ نشر
    2017-08-01
    1396-05-10
    ناشر
    Iranian Association of Chemical Engineers(IAChE)
    سازمان پدید آورنده
    School of Chemical Engineering, Faculty of Engineering, University of Tehran, Tehran, Iran
    Materials and Nuclear Fuel Research School, Nuclear Science and Technology Research Institute, Tehran, Iran
    School of Chemical Engineering, Faculty of Engineering, University of Tehran, Tehran, Iran
    School of Chemical Engineering, Faculty of Engineering, University of Tehran, Tehran, Iran
    Materials and Nuclear Fuel Research School, Nuclear Science and Technology Research Institute, Tehran, Iran

    شاپا
    1735-5397
    2008-2355
    URI
    http://www.ijche.com/article_51453.html
    https://iranjournals.nlai.ir/handle/123456789/83523

    Related items

    Showing items related by title, author, creator and subject.

    • Determination of Two Antiepileptic Drugs in Urine by Homogenous Liquid-Liquid Extraction Performed in A Narrow Tube Combined With Dispersive Liquid-liquid Microextraction Followed by Gas Chromatography-flame Ionization Detection 

      Feriduni, Behruz؛ Farajzadeh, Mir Ali؛ Jouyban, Abolghasem (School of Pharmacy, Shahid Beheshti University of Medical Sciences, 2019-05-01)
      A simple and efficient homogenous liquid-liquid extraction method performed in a narrow tube combined with dispersive liquid-liquid microextraction method has been presented for the simultaneous determination of two ...

    • Ionic Liquid-Based Dispersive Liquid-Liquid Microextraction Coupled with High Performance Liquid Chromatography for the Determination of Spirotetramat in Water Samples 

      Nourpishe, Fatemeh؛ Amiri, Ali Asghar؛ Sheibani, Ali؛ Shishehbore, Masoud Reza (Payame Noor University, Iranدانشگاه پیام نور, 2020-03-01)
      In this study, a simple and sensitive method was developed for pre-concentration of spirotetramat (SPT) using the ionic liquid-based dispersive liquid-liquid microextraction. After extracting of SPT into 1-butyl-3-methyl ...

    • Nonrandom Two-Liquid Model with Differential Evolution for Experimental Liquid-Liquid Equilibrium Calculation 

      Hebboul, Sabrina؛ Bacha, Oussama؛ Korichi, Mourad؛ Hebboul, Amel (Iranian Institute of Research and Development in Chemical Industries (IRDCI)-ACECR, 2024-12-01)
      In this study, the NonRandom Two-Liquid (NRTL) model was used to calculate the isoactivity equations from the experimental Liquid-Liquid Equilibrium (LLE) data. Additionally, the original Differential Evolution method ...

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب