• ورود به سامانه
      مشاهده مورد 
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Iranian Journal of Pharmaceutical Sciences
      • Volume 14, Issue 1
      • مشاهده مورد
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Iranian Journal of Pharmaceutical Sciences
      • Volume 14, Issue 1
      • مشاهده مورد
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      Simultaneous estimation of amlodipine besylate and nebivolol hydrochloride in pharmaceutical tablets formulation by RP-HPLC using PDA detector

      (ندگان)پدیدآور
      Kumar, SinhaDebnath, ManidipaSreenu, MendeliSingh, Mahesh
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      694.0کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Research Paper
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Background: The present work was undertaken with the aim to develop and validate a rapid and consistent RP-HPLC method in which the peaks will be appear with short period of time as per ICH Guidelines. Materials and Methods: The separation was achieved on a a stainless steel analytical column, Eclipse XDB plus C18 column (4.6 X 150 mm; 5 μm) in an isocratic mode. The mobile phase was composed acetonitrile and 0.01 M ammonium acetate (pH adjusted to 4.5 using glacial acetic acid), which were mixed in the ratio of 50 : 50. The flow rate was monitored at 1.0 mL/min. The wavelength selected for detection was 265 nm. Results: The retention time found for amlodipine besylate and nebivolol hydrochloride was 2.967 and 3.510 min respectively. The % recovery was 100.20- 100.86 for amlodipine and 100.20 - 100.78 for nebivolol. The linearity was established in the range of 5-25 µg/mL for amlodipine and 10-50 µg/mL for nebivolol. The slope, intercept, and correlation coefficient were found to be 314.2x, +162.4, and 0.999 for amlodipine besylate and 248x, -305.7, and 0.9998 for nebivolol hydrochloride, respectively. The limits of detection for amlodipine besylate and nebivolol hydrochloride obtained by the proposed method was 0.07 and 0.20 µg/ml and limits of quantification for amlodipine besylate and nebivolol hydrochloride obtained by the proposed method was 0.23 and 0.61 μg/mL respectively. Conclusion: The method was found to be suitable for the quality control test of amlodipine besylate and nebivolol hydrochloride simultaneously in a bulk drugs as well as in a formulations.
      کلید واژگان
      Amlodipine besylate
      isocratic separation
      Validation
      nebivolol hydrochloride
      RP-HPLC
      C18 column
      Other pharmacy related topics

      شماره نشریه
      1
      تاریخ نشر
      2018-01-01
      1396-10-11
      ناشر
      Iranian Association of Pharmaceutical Scientists
      سازمان پدید آورنده
      Department of Pharmacy, Tripura University (A Central University), Suryamaninagar, Agartala, Tripura, 799022
      Inspecting Officer (Drugs), O/o. The Deputy Drugs Controller, Pandit Nehru Complex, Gourkhabasti, Agartala, Tripura, 799006.
      Department of Pharmaceutical Analysis and Quality Assurance, A.K.R.G College of Pharmacy, Nallajerla, West Godavari, 534112, A.P
      Dean & HOD, Department of Pharmacy, Tripura University, (A Central University), Suryamaninagar, Agartala-799022

      شاپا
      1735-2444
      URI
      https://dx.doi.org/10.22034/ijps.2018.32048
      http://www.ijps.ir/article_32048.html
      https://iranjournals.nlai.ir/handle/123456789/79285

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب