• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Pharmaceutical Sciences
    • Volume 14, Issue 1
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Pharmaceutical Sciences
    • Volume 14, Issue 1
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Simultaneous estimation of amlodipine besylate and nebivolol hydrochloride in pharmaceutical tablets formulation by RP-HPLC using PDA detector

    (ندگان)پدیدآور
    Kumar, SinhaDebnath, ManidipaSreenu, MendeliSingh, Mahesh
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    694.0کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Research Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Background: The present work was undertaken with the aim to develop and validate a rapid and consistent RP-HPLC method in which the peaks will be appear with short period of time as per ICH Guidelines. Materials and Methods: The separation was achieved on a a stainless steel analytical column, Eclipse XDB plus C18 column (4.6 X 150 mm; 5 μm) in an isocratic mode. The mobile phase was composed acetonitrile and 0.01 M ammonium acetate (pH adjusted to 4.5 using glacial acetic acid), which were mixed in the ratio of 50 : 50. The flow rate was monitored at 1.0 mL/min. The wavelength selected for detection was 265 nm. Results: The retention time found for amlodipine besylate and nebivolol hydrochloride was 2.967 and 3.510 min respectively. The % recovery was 100.20- 100.86 for amlodipine and 100.20 - 100.78 for nebivolol. The linearity was established in the range of 5-25 µg/mL for amlodipine and 10-50 µg/mL for nebivolol. The slope, intercept, and correlation coefficient were found to be 314.2x, +162.4, and 0.999 for amlodipine besylate and 248x, -305.7, and 0.9998 for nebivolol hydrochloride, respectively. The limits of detection for amlodipine besylate and nebivolol hydrochloride obtained by the proposed method was 0.07 and 0.20 µg/ml and limits of quantification for amlodipine besylate and nebivolol hydrochloride obtained by the proposed method was 0.23 and 0.61 μg/mL respectively. Conclusion: The method was found to be suitable for the quality control test of amlodipine besylate and nebivolol hydrochloride simultaneously in a bulk drugs as well as in a formulations.
    کلید واژگان
    Amlodipine besylate
    isocratic separation
    Validation
    nebivolol hydrochloride
    RP-HPLC
    C18 column
    Other pharmacy related topics

    شماره نشریه
    1
    تاریخ نشر
    2018-01-01
    1396-10-11
    ناشر
    Iranian Association of Pharmaceutical Scientists
    سازمان پدید آورنده
    Department of Pharmacy, Tripura University (A Central University), Suryamaninagar, Agartala, Tripura, 799022
    Inspecting Officer (Drugs), O/o. The Deputy Drugs Controller, Pandit Nehru Complex, Gourkhabasti, Agartala, Tripura, 799006.
    Department of Pharmaceutical Analysis and Quality Assurance, A.K.R.G College of Pharmacy, Nallajerla, West Godavari, 534112, A.P
    Dean & HOD, Department of Pharmacy, Tripura University, (A Central University), Suryamaninagar, Agartala-799022

    شاپا
    1735-2444
    URI
    https://dx.doi.org/10.22034/ijps.2018.32048
    http://www.ijps.ir/article_32048.html
    https://iranjournals.nlai.ir/handle/123456789/79285

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب