• ورود به سامانه
      مشاهده مورد 
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Iranian Journal of Pharmaceutical Sciences
      • Volume 12, Issue 1
      • مشاهده مورد
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Iranian Journal of Pharmaceutical Sciences
      • Volume 12, Issue 1
      • مشاهده مورد
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      Ion Selective Carbon Paste Electrode For The Determination Of Flavoxate Muscle Relaxant Drug In Pharmaceutical Formulation

      (ندگان)پدیدآور
      Ismail, Nahla
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      555.1کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Research Paper
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Abstract The utility of carbon paste electrode for the determination of flavoxate HCl modified with flavoxate-tetraphenylborate (FLX-TPB) and flavoxate-phosphotungestic acid (FLX-PTA) ion-pairs in batch mode is demonstrated. The electrodes revealed a Nernstian response over a wide concentration ranges 1.39×10-5-1x10-2 mol L-1 and1×10-5-1x10-2 mol L-1 using FLX-TPB and FLX-PTA, respectively. The detection limits of these sensors are 1.39×10-5 mol L-1, and 1x10-6 mol L-1 using FLX-TPB and FLX-PTA, respectively. The best performance was obtained with carbon paste composition of 5% flavoxate-tetraphenylborate or flavoxate-phosphotungestate, 47.5% graphite and 47.5% o- nitro phenyl octyl ether (o-NPOE). The sensors exhibit a very fast response time (5-7 s) and good selectivity in presence of inorganic cations, sugars and aminoacids. The proposed sensors show great improvement in comparison with other previously reported sensors. The sensors were successfully applied to monitoring of flavoxate in pure solution and pharmaceutical formulation (Genurin tablet) with recovery ranges from 97.2 – 101.0% and 98.1-101.6% using FLX-TPB and FLX-PTA, respectively.
      کلید واژگان
      Flavoxate
      Carbon paste
      ionselective electrode
      Potentiometry
      batch mode
      Sensors
      Pharmaceutical chemistry

      شماره نشریه
      1
      تاریخ نشر
      2016-01-01
      1394-10-11
      ناشر
      Iranian Association of Pharmaceutical Scientists
      سازمان پدید آورنده
      NODCAR

      شاپا
      1735-2444
      URI
      https://dx.doi.org/10.22034/ijps.2016.19004
      http://www.ijps.ir/article_19004.html
      https://iranjournals.nlai.ir/handle/123456789/79233

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب