    Ion Selective Carbon Paste Electrode For The Determination Of Flavoxate Muscle Relaxant Drug In Pharmaceutical Formulation

    (ندگان)پدیدآور
    Ismail, Nahla
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    555.1کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Research Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Abstract The utility of carbon paste electrode for the determination of flavoxate HCl modified with flavoxate-tetraphenylborate (FLX-TPB) and flavoxate-phosphotungestic acid (FLX-PTA) ion-pairs in batch mode is demonstrated. The electrodes revealed a Nernstian response over a wide concentration ranges 1.39×10-5-1x10-2 mol L-1 and1×10-5-1x10-2 mol L-1 using FLX-TPB and FLX-PTA, respectively. The detection limits of these sensors are 1.39×10-5 mol L-1, and 1x10-6 mol L-1 using FLX-TPB and FLX-PTA, respectively. The best performance was obtained with carbon paste composition of 5% flavoxate-tetraphenylborate or flavoxate-phosphotungestate, 47.5% graphite and 47.5% o- nitro phenyl octyl ether (o-NPOE). The sensors exhibit a very fast response time (5-7 s) and good selectivity in presence of inorganic cations, sugars and aminoacids. The proposed sensors show great improvement in comparison with other previously reported sensors. The sensors were successfully applied to monitoring of flavoxate in pure solution and pharmaceutical formulation (Genurin tablet) with recovery ranges from 97.2 – 101.0% and 98.1-101.6% using FLX-TPB and FLX-PTA, respectively.
    کلید واژگان
    Flavoxate
    Carbon paste
    ionselective electrode
    Potentiometry
    batch mode
    Sensors
    Pharmaceutical chemistry

    شماره نشریه
    1
    تاریخ نشر
    2016-01-01
    1394-10-11
    ناشر
    Iranian Association of Pharmaceutical Scientists
    سازمان پدید آورنده
    NODCAR

    شاپا
    1735-2444
    URI
    https://dx.doi.org/10.22034/ijps.2016.19004
    http://www.ijps.ir/article_19004.html
    https://iranjournals.nlai.ir/handle/123456789/79233

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب