• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Asia Oceania Journal of Nuclear Medicine and Biology
    • Volume 3, Issue 2
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Asia Oceania Journal of Nuclear Medicine and Biology
    • Volume 3, Issue 2
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Usefulness of an Automatic Quantitative Method for Measuring Regional Cerebral Blood Flow Using 99mTc Ethyl Cysteinate Dimer Brain Uptake Ratio

    (ندگان)پدیدآور
    Nagaoka, RiekoOfuji, AsatoYamashita, KosukeTomimatsu, TaekoOrita, ShinnichiTakaki, AkihiroUchiyama, YoshikazuIto, Shigeki
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    701.1کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Technical note
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Objective(s): Improved brain uptake ratio (IBUR), employing 99mTc-ethyl cysteinate dimer (99mTc-ECD), is an automatic non-invasive method for quantitatively measuring regional cerebral blood flow (rCBF). This method was developed by the reconstruction of the theory and linear regression equation, based on rCBF measurement by H215O positron emission tomography. Clarification of differences in rCBF values obtained by Patlak plot (PP) and IBUR method is important for clinical diagnosis during the transition period between these methods. Our purpose in this study was to demonstrate the relationship between rCBF values obtained by IBUR and PP methods and to evaluate the clinical applicability of IBUR method. Methods: The mean CBF (mCBF) and rCBF values in 15 patients were obtained using the IBUR method and compared with PP method values. Results: Overall, mCBF and rCBF values, obtained using these independent techniques, were found to be correlated (r=0.68). The mCBF values obtained by the IBUR method ranged from 18.9 to 44.9 ml/100g/min, whereas those obtained by the PP method ranged from 34.7 to 48.1 ml/100g/min. The rCBF values obtained by the IBUR method ranged from 16.3 to 60.2 ml/100g/min, whereas those obtained by the PP method were within the range of 26.7-58.8 ml/100g/min. Conclusion: The ranges of mCBF and rCBF values, obtained by the IBUR method, were approximately 60% lower than those obtained by the PP method; therefore, this method can be useful for diagnosing lower flow area. Re-analysis of prior PP data, using the IBUR method, could be potentially useful for the clinical follow-up of rCBF.    
    کلید واژگان
    rCBF
    99mTc-ECD
    brain uptake
    Patlak plot
    SPECT
    Neurology
    Nuclear Medicine

    شماره نشریه
    2
    تاریخ نشر
    2015-07-01
    1394-04-10
    ناشر
    Asia Oceania Federation of Nuclear Medicine & Biology
    سازمان پدید آورنده
    Department of Radiology, Clinical Research Institute, National Hospital Organization Kyushu Medical Center, Fukoka, Japan
    Graduate School of Health Sciences, Kumamoto University, Kumamoto, Japan
    Graduate School of Health Sciences, Kumamoto University, Kumamoto, Japan
    Department of Radiology, Clinical Research Institute, National Hospital Organization Kyushu Medical Center, Fukoka, Japan
    Department of Radiology, Clinical Research Institute, National Hospital Organization Kyushu Medical Center, Fukoka, Japan
    Fujifilm RI Pharma Co., Ltd., Tokyo, Japan
    Department of Medical Imaging, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan
    Department of Medical Imaging, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan

    شاپا
    2322-5718
    2322-5726
    URI
    https://dx.doi.org/10.7508/aojnmb.2015.02.002
    http://aojnmb.mums.ac.ir/article_3842.html
    https://iranjournals.nlai.ir/handle/123456789/420944

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب