نمایش مختصر رکورد

dc.contributor.authorNagaoka, Riekoen_US
dc.contributor.authorOfuji, Asatoen_US
dc.contributor.authorYamashita, Kosukeen_US
dc.contributor.authorTomimatsu, Taekoen_US
dc.contributor.authorOrita, Shinnichien_US
dc.contributor.authorTakaki, Akihiroen_US
dc.contributor.authorUchiyama, Yoshikazuen_US
dc.contributor.authorIto, Shigekien_US
dc.date.accessioned1399-07-09T12:23:01Zfa_IR
dc.date.accessioned2020-09-30T12:23:01Z
dc.date.available1399-07-09T12:23:01Zfa_IR
dc.date.available2020-09-30T12:23:01Z
dc.date.issued2015-07-01en_US
dc.date.issued1394-04-10fa_IR
dc.date.submitted2014-08-23en_US
dc.date.submitted1393-06-01fa_IR
dc.identifier.citationNagaoka, Rieko, Ofuji, Asato, Yamashita, Kosuke, Tomimatsu, Taeko, Orita, Shinnichi, Takaki, Akihiro, Uchiyama, Yoshikazu, Ito, Shigeki. (2015). Usefulness of an Automatic Quantitative Method for Measuring Regional Cerebral Blood Flow Using 99mTc Ethyl Cysteinate Dimer Brain Uptake Ratio. Asia Oceania Journal of Nuclear Medicine and Biology, 3(2), 77-82. doi: 10.7508/aojnmb.2015.02.002en_US
dc.identifier.issn2322-5718
dc.identifier.issn2322-5726
dc.identifier.urihttps://dx.doi.org/10.7508/aojnmb.2015.02.002
dc.identifier.urihttp://aojnmb.mums.ac.ir/article_3842.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/420944
dc.description.abstract<em>Objective(s): </em>Improved brain uptake ratio (IBUR), employing 99mTc-ethyl cysteinate dimer (99mTc-ECD), is an automatic non-invasive method for quantitatively measuring regional cerebral blood flow (rCBF). This method was developed by the reconstruction of the theory and linear regression equation, based on rCBF measurement by H<sub>2</sub>15O positron emission tomography. Clarification of differences in rCBF values obtained by Patlak plot (PP) and IBUR method is important for clinical diagnosis during the transition period between these methods. Our purpose in this study was to demonstrate the relationship between rCBF values obtained by IBUR and PP methods and to evaluate the clinical applicability of IBUR method. <br/><em>Methods: </em>The mean CBF (mCBF) and rCBF values in 15 patients were obtained using the IBUR method and compared with PP method values. <br/><em>Results: </em>Overall, mCBF and rCBF values, obtained using these independent techniques, were found to be correlated (<em>r</em>=0.68). The mCBF values obtained by the IBUR method ranged from 18.9 to 44.9 ml/100g/min, whereas those obtained by the PP method ranged from 34.7 to 48.1 ml/100g/min. The rCBF values obtained by the IBUR method ranged from 16.3 to 60.2 ml/100g/min, whereas those obtained by the PP method were within the range of 26.7-58.8 ml/100g/min. <br/><em>Conclusion: </em>The ranges of mCBF and rCBF values, obtained by the IBUR method, were approximately 60% lower than those obtained by the PP method; therefore, this method can be useful for diagnosing lower flow area. Re-analysis of prior PP data, using the IBUR method, could be potentially useful for the clinical follow-up of rCBF. <br/>  <br/>  <br/>en_US
dc.format.extent700
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherAsia Oceania Federation of Nuclear Medicine & Biologyen_US
dc.relation.ispartofAsia Oceania Journal of Nuclear Medicine and Biologyen_US
dc.relation.isversionofhttps://dx.doi.org/10.7508/aojnmb.2015.02.002
dc.subjectrCBFen_US
dc.subject99mTc-ECDen_US
dc.subjectbrain uptakeen_US
dc.subjectPatlak ploten_US
dc.subjectSPECTen_US
dc.subjectNeurologyen_US
dc.subjectNuclear Medicineen_US
dc.titleUsefulness of an Automatic Quantitative Method for Measuring Regional Cerebral Blood Flow Using 99mTc Ethyl Cysteinate Dimer Brain Uptake Ratioen_US
dc.typeTexten_US
dc.typeTechnical noteen_US
dc.contributor.departmentDepartment of Radiology, Clinical Research Institute, National Hospital Organization Kyushu Medical Center, Fukoka, Japanen_US
dc.contributor.departmentGraduate School of Health Sciences, Kumamoto University, Kumamoto, Japanen_US
dc.contributor.departmentGraduate School of Health Sciences, Kumamoto University, Kumamoto, Japanen_US
dc.contributor.departmentDepartment of Radiology, Clinical Research Institute, National Hospital Organization Kyushu Medical Center, Fukoka, Japanen_US
dc.contributor.departmentDepartment of Radiology, Clinical Research Institute, National Hospital Organization Kyushu Medical Center, Fukoka, Japanen_US
dc.contributor.departmentFujifilm RI Pharma Co., Ltd., Tokyo, Japanen_US
dc.contributor.departmentDepartment of Medical Imaging, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japanen_US
dc.contributor.departmentDepartment of Medical Imaging, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japanen_US
dc.citation.volume3
dc.citation.issue2
dc.citation.spage77
dc.citation.epage82


فایل‌های این مورد

Thumbnail

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد