    Utilization of Electronic Portal Imaging Device (EPID) For Setup Verification and Determination of Setup Margin in Head and Neck Radiation Therapy

    (ندگان)پدیدآور
    vejdani noghreiyan, vajihehnaseri, shahrokhMomennezhad, Mehdi
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.188 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction: Radiation therapy involves a multistep procedure; therefore, the error in patient set up is an inherent part of the treatment. Main purpose of this study was to determine the clinical target volume (CTV) to planning target volume (PTV) in head and neck cancer patients. Material and Methods: A total of 15 patients who had daily portal images during the treatment courses were randomly selected in the present study. Systematic (Σ) and random (σ) errors were evaluated in three directions. The Isogray treatment planning system and Elekta linear accelerator were used in this study. Moreover, we had used MOSIAQ software as arecord and Verify system. Setup margins were calculated using three published margin recipes, including the International Commission on Radiation Units and Measurements (ICRU) report 62, as well as Stroom's and van Herk's formulae. Results: Average magnitude of the translational errors was reported between 0.7 and 10 mm. The systematic and random errors for head and neck cancer patients were 3.55 (2.58-4.52) and 1.83 (1.56-2.10) mm, respectively. According to the ICRU report 62, as well as Stoorm's and van Herk's formulas, the required margins to cover the target were obtained within the ranges of 3.1-4.9, 6.4-10.5, and 7.7-12.7 mm, respectively. Conclusion: According to the results of the present study, 6.5-10.5 mm extension in CTV to PTV margin can ensure that 90% of the head and neck cancer patients will receive a minimum cumulative CTV dose higher than or equal to 95% of the prescribed dose.
    کلید واژگان
    Image Guided
    systematic errors
    random errors
    Cancer of head and neck
    CTV To PTV Margin
    Medical Physics
    Physics of Radiotherapy

    شماره نشریه
    3
    تاریخ نشر
    2020-05-01
    1399-02-12
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
    Department of medical physics, Faulty of medicine, Mashhad University of Medical Sciences, Mashhad, Iran
    Nuclear Medicine Research Center, Mashhad University of Medical Sciences, Mashhad, Iran

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2019.41861.1612
    http://ijmp.mums.ac.ir/article_13756.html
    https://iranjournals.nlai.ir/handle/123456789/324854

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب