مرور Volume 17, Issue 3 بر اساس تاریخ انتشار
در حال نمایش موارد 1 - 9 از 9
-
Utilization of Electronic Portal Imaging Device (EPID) For Setup Verification and Determination of Setup Margin in Head and Neck Radiation Therapy
(Mashhad University of Medical Sciences, 2020-05-01)Introduction: Radiation therapy involves a multistep procedure; therefore, the error in patient set up is an inherent part of the treatment. Main purpose of this study was to determine the clinical ...
-
Introduction of a Reliable Software for the Calculation of the Gamma Index
(Mashhad University of Medical Sciences, 2020-05-01)Introduction: The gamma index is a known parameter for radiotherapy dose verification. Many free and commercial programs have been written for the calculation of this index. However, the verification ...
-
Comparing IDREAM as an Iterative Reconstruction Algorithm against In Filtered Back Projection in Computed Tomography
(Mashhad University of Medical Sciences, 2020-05-01)Introduction: Recent studies of Computed Tomography (CT) conducted on patient dose reduction have recommended using an iterative reconstruction algorithm and mA (mili-Ampere) dose modulation. The ...
-
Effect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies
(Mashhad University of Medical Sciences, 2020-05-01)Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of ...
-
Effects of Low Dose Gamma Ray on Some Hematological Parameters in Adult Rats
(Mashhad University of Medical Sciences, 2020-05-01)Introduction: The study aimed to find the low dose effect gamma ray on some hematological parameters in male albino rats obtained from the Mosul University, IRAQ, and also studied the radioprotective ...
-
Characterization of Wedge Factors and Dose Distributions in Radiotherapy with Symmetric and Asymmetric Physical Wedged Beams of 6 MV Photon Beam
(Mashhad University of Medical Sciences, 2020-05-01)Introduction: Physical wedge by modify photon beam shape and intensity has been utilized in radiotherapy to obtain uniformly dose distribution in tumor site with reduced hot spots. Calculation of ...
-
Fabrication and Characterization of Bolus Material Using Propylene Glycol for Radiation Therapy
(Mashhad University of Medical Sciences, 2020-05-01)Introduction: This study aimed to evaluate the efficacy of a synthesized bolus in the reduction of damage to body tissues and the protection of the organ at risk (OAR) in radiotherapy application. ...
-
Estimation of Occupational Exposure during Ceramic Manufacturing
(Mashhad University of Medical Sciences, 2020-05-01)Introduction: The present study investigated the relatively high concentrations of natural radionuclides in raw material that used in ceramic manufacturing, and estimated the occupational exposure ...
-
Optimization of Imaging Parameters in Micro-CT Scanner Based On Signal-To-Noise Ratio for the Analysis of Urinary Stone Composition
(Mashhad University of Medical Sciences, 2020-05-01)Introduction: Micro-CT scanner with a resolution of about 5 micrometers is one of the modalities used to create three-dimensional/two-dimensional images of urinary stones. This study aimed to ...