• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Medical Physics
    • Volume 10, Issue 2
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Medical Physics
    • Volume 10, Issue 2
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    A New Method for Metal Artifact Reduction in CT Scan Images

    (ندگان)پدیدآور
    Safdari, MohsenKarimian, AlirezaYazdchi, Mohammad reza
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    2.433 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Introduction In CT imaging, metallic implants inside the tissues cause metal artifact that reduce the quality of image for diagnosis. In order to reduce the effect of this artifact, a new method with more appropriate results has been presented in this research work. Materials and Methods The presented method comprised of following steps: a) image enhancement and metal areas extraction, b) sinogram transform of original image, c) metal segments and metal traces inside the sinogram transform of original image segmented by using Fuzzy C means, d) interpolation of metal traces inside the original image sinogram and filtering, and e) adding the image of metal parts to the filtered image to obtain the corrected image. Results Fifty CT scan images from Alzahra Hospital in Isfahan were used to evaluate the proposed method. The proposed method was applied to images which had implants in regions such as femur, hip, tooth, brain, and stomach. The results showed an intensively reduced in metal artifact and quality improvement of images till 90% for accuracy, compared with the radiologist report. Conclusion The proposed method reduced the effect of metal artifact by maintaining the specification of other tissues. Furthermore, the consumed time to process the suggested algorithm in this study was less than conventional methods. For instance, the consumed time for CT image, including a metal in the femur region was about 20% of the conventional method.
    کلید واژگان
    CT Scan
    Interpolation
    Metal Artifact
    Computed Tomography (CT)
    Medical Application of Computer Simulation
    Medical Physics

    شماره نشریه
    2
    تاریخ نشر
    2013-09-01
    1392-06-10
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Department of Biomedical Engineering, University Of Isfahan, Hezarjerib Street, Isfahan, Iran,
    Department of Biomedical Engineering, Faculty of Engineering, University of Isfahan, Hezarjerib Street, Isfahan, Iran
    Department of Biomedical Engineering, Faculty of Engineering, University of Isfahan, Hezarjerib Street, Isfahan, Iran

    شاپا
    2345-3672
    URI
    https://dx.doi.org/10.22038/ijmp.2013.2182
    http://ijmp.mums.ac.ir/article_2182.html
    https://iranjournals.nlai.ir/handle/123456789/324815

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب