نمایش مختصر رکورد

dc.contributor.authorSafdari, Mohsenen_US
dc.contributor.authorKarimian, Alirezaen_US
dc.contributor.authorYazdchi, Mohammad rezaen_US
dc.date.accessioned1399-07-09T07:35:06Zfa_IR
dc.date.accessioned2020-09-30T07:35:06Z
dc.date.available1399-07-09T07:35:06Zfa_IR
dc.date.available2020-09-30T07:35:06Z
dc.date.issued2013-09-01en_US
dc.date.issued1392-06-10fa_IR
dc.date.submitted2012-11-18en_US
dc.date.submitted1391-08-28fa_IR
dc.identifier.citationSafdari, Mohsen, Karimian, Alireza, Yazdchi, Mohammad reza. (2013). A New Method for Metal Artifact Reduction in CT Scan Images. Iranian Journal of Medical Physics, 10(2), 139-146. doi: 10.22038/ijmp.2013.2182en_US
dc.identifier.issn2345-3672
dc.identifier.urihttps://dx.doi.org/10.22038/ijmp.2013.2182
dc.identifier.urihttp://ijmp.mums.ac.ir/article_2182.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/324815
dc.description.abstractIntroduction <br/>In CT imaging, metallic implants inside the tissues cause metal artifact that reduce the quality of image for diagnosis. In order to reduce the effect of this artifact, a new method with more appropriate results has been presented in this research work. <br/>Materials and Methods <br/>The presented method comprised of following steps: a) image enhancement and metal areas extraction, b) sinogram transform of original image, c) metal segments and metal traces inside the sinogram transform of original image segmented by using Fuzzy C means, d) interpolation of metal traces inside the original image sinogram and filtering, and e) adding the image of metal parts to the filtered image to obtain the corrected image. <br/>Results <br/>Fifty CT scan images from Alzahra Hospital in Isfahan were used to evaluate the proposed method. The proposed method was applied to images which had implants in regions such as femur, hip, tooth, brain, and stomach. The results showed an intensively reduced in metal artifact and quality improvement of images till 90% for accuracy, compared with the radiologist report. <br/>Conclusion <br/>The proposed method reduced the effect of metal artifact by maintaining the specification of other tissues. Furthermore, the consumed time to process the suggested algorithm in this study was less than conventional methods. For instance, the consumed time for CT image, including a metal in the femur region was about 20% of the conventional method.en_US
dc.format.extent2491
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherMashhad University of Medical Sciencesen_US
dc.relation.ispartofIranian Journal of Medical Physicsen_US
dc.relation.isversionofhttps://dx.doi.org/10.22038/ijmp.2013.2182
dc.subjectCT Scanen_US
dc.subjectInterpolationen_US
dc.subjectMetal Artifacten_US
dc.subjectComputed Tomography (CT)en_US
dc.subjectMedical Application of Computer Simulationen_US
dc.subjectMedical Physicsen_US
dc.titleA New Method for Metal Artifact Reduction in CT Scan Imagesen_US
dc.typeTexten_US
dc.typeOriginal Paperen_US
dc.contributor.departmentDepartment of Biomedical Engineering, University Of Isfahan, Hezarjerib Street, Isfahan, Iran,en_US
dc.contributor.departmentDepartment of Biomedical Engineering, Faculty of Engineering, University of Isfahan, Hezarjerib Street, Isfahan, Iranen_US
dc.contributor.departmentDepartment of Biomedical Engineering, Faculty of Engineering, University of Isfahan, Hezarjerib Street, Isfahan, Iranen_US
dc.citation.volume10
dc.citation.issue2
dc.citation.spage139
dc.citation.epage146


فایل‌های این مورد

Thumbnail

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد