    Determination of Noise Level and Its Sources in the Neonatal Intensive Care Unit and Neonatal Ward

    (ندگان)پدیدآور
    Jahangir Blourchian, MahdiSharafi, Reza
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.382 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Background: In Neonatal intensive care units (NICU) different sound intensities and frequencies are produced from different sources, which may exert undesirable physiological effects on the infants. The aim of this study was to determine the noise level and its sources in the NICU and neonatal ward of Al-Zahra Hospital of Rasht, Iran. Methods: In this descriptive cross-sectional study, the intensity of the sounds generated by the internal and external sources in the NICU and neonatal ward was measured using a sound level meter device. The sound produced by each of the sources was individually calculated. Data were analyzed performing descriptive and analytical statistics, using SPSS version 19. Results: The mean noise levels in six rooms and a hallway during morning, afternoon and night shifts with the electromechanical devices turned on were 61.67±4.5, 61.32±4.32 and 60.71±4.56 dB, respectively. Moreover, with the devices tuned off the mean noise levels during morning, afternoon and evening shifts were 64.97±2.6, 60.6±1.29 and 57.91±4.73 dB, respectively. The differences between the mean noise levels in the neonatal wards (standard noise level=45 dB) during each shift with the electromechanical devices turned on and off were statistically significant (P=0.002 and PConclusion: According to the obtained results, the highest noise levels were generated by the electromechanical devices inside the NICU and neonatal ward, and there were no significant differences in the noise level with the devices turned on and off. Moreover, personnel's noise-generating behaviors were the main sources of noise. Therefore, it seems that providing educational preparation for the staff can diminish the ambient noise level.
    کلید واژگان
    Intensive Care Unit
    Noise pollution
    neonate

    شماره نشریه
    4
    تاریخ نشر
    2015-12-01
    1394-09-10
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Research Center of Health, School of Health, Guilan University of Medical Sciences, Rasht, Iran
    Pediatrics Growth Disorders Research Center, 17 Shahrivar Hospital, School of Medicine, Guilan University of Medical Sciences, Rasht, Iran

    شاپا
    2251-7510
    2322-2158
    URI
    https://dx.doi.org/10.22038/ijn.2015.6144
    http://ijn.mums.ac.ir/article_6144.html
    https://iranjournals.nlai.ir/handle/123456789/323207

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب