• ورود به سامانه
      مشاهده مورد 
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Iranian Journal of Pharmaceutical Research
      • Volume 15, Special Issue
      • مشاهده مورد
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Iranian Journal of Pharmaceutical Research
      • Volume 15, Special Issue
      • مشاهده مورد
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      Design and Optimization of a New Voltammetric Method for Determination of Isoniazid by Using PEDOT Modified Gold Electrode in Pharmaceuticals

      (ندگان)پدیدآور
      Demirkaya-Miloglu, FatmaOznuluer, TubaOzdurak, BuketMiloglu, Elmas
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      1.059 مگابایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Research article
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Isoniazid (INH) was studied with regard to its electrochemical treatment on a strongly alkaline solution of a poly (3,4-ethylenedioxythiophene)-modified gold electrode, using both cyclic voltammetry and controlled potential techniques. This composite electrode exhibited 4-fold higher oxidation of INH, in accordance with peak densities, than the bare gold electrode. It was used the central composite design method to obtain optimum experimental conditions, and used critical parameters (pH (A), scan rate (mV/s, B) and temperature (C, C) to assess the effects on amperometric response. Optimum experimental conditions were achieved by using a pH of 9.2 with a scan rate of 260 mV/s and a temperature of 30C. Under these conditions, a good linear relationship was observed between peak current densities and INH concentration in the range of 0.05-2 μM, with correlation coefficient of 0.9998. Furthermore, the method was very sensitive (limit of quantitation, 0.0043 μM), accurate (relative error, -5.65 to 4.03) and precise (relative standard deviation %, ≤7.97). The method was also applied to determine INH in pharmaceutical formulations, and statistically compared the results with the official method using the two one-sided equivalence test; the results were in good agreement with those obtained by the official and reported methods.
      کلید واژگان
      Isoniazid
      PEDOT modified electrode
      central composite design
      voltammetric method
      Drug quality control
      Pharmacutics

      تاریخ نشر
      2016-03-01
      1394-12-11
      ناشر
      School of Pharmacy, Shahid Beheshti University of Medical Sciences
      سازمان پدید آورنده
      Ataturk University
      Atatürk University
      Ataturk University
      Ataturk University

      شاپا
      1735-0328
      1726-6890
      URI
      https://dx.doi.org/10.22037/ijpr.2016.1807
      http://ijpr.sbmu.ac.ir/article_1807.html
      https://iranjournals.nlai.ir/handle/123456789/313596

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب