• ورود به سامانه
      مشاهده مورد 
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Iranian Journal of Pharmaceutical Research
      • Volume 14, Issue 3
      • مشاهده مورد
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Iranian Journal of Pharmaceutical Research
      • Volume 14, Issue 3
      • مشاهده مورد
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      Preconcentration and Determination of Mefenamic Acid in Pharmaceutical and Biological Fluid Samples by Polymer-grafted Silica Gel Solid-phase Extraction Following High Performance Liquid Chromatography

      (ندگان)پدیدآور
      Bagheri Sadeghi, HayedehAhmad Panahi1, HomayonMahabadi, MahsaMoniri, Elham
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      1.093 مگابایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Research article
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Abstract Mefenamic acid is a nonsteroidal anti-inflammatory drug (NSAID) that has analgesic,anti-infammatory and antipyretic actions. It is used to relieve mild to moderate pains. Solid-phase extraction of mefenamic acid by a polymer grafted to silica gel is reported . Poly allyl glycidyl ether/iminodiacetic acid-co-N, N-dimethylacrylamide was synthesized and grafted to silica gel and was used as an adsorbent for extraction of trace mefenamic acid in pharmaceutical and biological samples. Different factors affecting the extraction method were investigated and optimum conditions were obtained. The optimum pH value for sorption of mefenamic acid was 4.0.The sorption capacity of grafted adsorbent was 7.0 mg/g. The best eluent solvent was found to be trifluoroacetic acid-acetic acid in methanol with a recovery of 99.6%. The equilibrium adsorption data of mefenamic acid by grafted silica gel was analyzed by Langmuir model. The conformation of obtained data to Langmuir isotherm model reveals the homogeneous binding sites of grafted silica gel surface. Kinetic study of the mefenamic acid sorption by grafted silica gel indicates the good accessibility of the active sites in the grafted polymer. The sorption rate of the investigated mefenamic acid on the grafted silica gel was less than 5min.This novel synthesized adsorbent can be successfully applied for the extraction of trace mefenamic acid in human plasma, urine and pharmaceutical samples.
      کلید واژگان
      Keywords: Mefenamic acid
      Solid phase extraction
      High Performance Liquid Chromatography
      Pharmaceutical sample
      Biological sample
      Drug quality control
      Medicinal chemistry

      شماره نشریه
      3
      تاریخ نشر
      2015-07-01
      1394-04-10
      ناشر
      School of Pharmacy, Shahid Beheshti University of Medical Sciences
      سازمان پدید آورنده
      Department of Chemistry, Central Tehran Branch, Islamic Azad University, Tehran, Iran
      Department of Chemistry, Central Tehran Branch, Islamic Azad University, Tehran, Iran
      Department of Chemistry, Central Tehran Branch, Islamic Azad University, Tehran, Iran
      Department of Chemistry, Varamin (Pishva) Branch, Islamic Azad University, Varamin, Iran

      شاپا
      1735-0328
      1726-6890
      URI
      https://dx.doi.org/10.22037/ijpr.2015.1675
      http://ijpr.sbmu.ac.ir/article_1675.html
      https://iranjournals.nlai.ir/handle/123456789/313164

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب