• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Analytical and Bioanalytical Chemistry Research
    • Volume 6, Issue 2
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Analytical and Bioanalytical Chemistry Research
    • Volume 6, Issue 2
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Determination of 17-β-Estradiol in Water Samples Using Salting-out Assisted Liquid-liquid Extraction Followed by HPLC and Experimental Design for Optimization

    (ندگان)پدیدآور
    Hassannejad, MohammadAlizadeh, KamalNemati, Mahboob
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    545.6کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Research Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    The aim of the present study was to extract, preconcentrate and determine 17-β–Estradiol in water samples using a simple and efficient method; to this aim, salting-out-assisted liquid-liquid extraction and high-performance liquid chromatography with ultra violet detection at 210 nm were performed. Water-miscible acetonitrile, as the extractant and acetonitrile phase separation under high-salt conditions were applied to treat the samples. The extraction efficiency and method sensitivity were carefully monitored by controlling the effective factors and the optimum conditions were: Sodium chloride as the salting-out agent at concentration of 1.6 g, 2.40 mL of acetonitrile as extraction solvent, 5 mL of water sample, vortexing for 2 minutes and centrifuging at 4000 rpm for 5 minutes. A central composite design was applied to optimize the hydrolysis parameters. Using optimized experimental conditions, the calibration curve was found to be linear in the range of 1–120 µg L-1 in water sample and the correlation coefficient (R2); the limit of detection; limit of quantification were >0.99, 0.25 µg mL-1 and 0.83 μgL-1, respectively. The enrichment factor and extraction recoveries of the selected analyte ranged from 44.96 to 49.57 and 89.93 to 99.15% respectively. Relative standard deviations are about 5.94%. High extraction efficiency and compatibility with HPLC analysis of 17-β–Estradiol in water samples are the advantages of this method.
    کلید واژگان
    Salting-out-assisted
    liquid-liquid extraction
    17-β-Estradiol
    Central composite design

    شماره نشریه
    2
    تاریخ نشر
    2019-12-01
    1398-09-10
    ناشر
    Iranian Chemical Society
    سازمان پدید آورنده
    Department of Chemistry, Lorestan University, Khorramabad 6813717133, Iran
    Department of Chemistry, Lorestan University, Khorramabad 6813717133, Iran
    Department of Chemistry, Tabriz University of Medical Sciences, Tabriz 1476651664, Iran

    شاپا
    2383-093X
    URI
    https://dx.doi.org/10.22036/abcr.2019.151886.1261
    http://www.analchemres.org/article_85317.html
    https://iranjournals.nlai.ir/handle/123456789/99416

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب