• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Analytical and Bioanalytical Chemistry Research
    • Volume 7, Issue 1
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Analytical and Bioanalytical Chemistry Research
    • Volume 7, Issue 1
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Determination of Organic Sulfur Contaminants Using Hollow Fibre-protected Liquid-phase Micro-extraction Coupled with Gas Chromatography

    (ندگان)پدیدآور
    Hojjati, MohammadHaghighi, Tarlan
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1015.کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Research Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    A simple and solvent-minimized sample preparation technique based on hollow fibre-protected liquid-phase micro-extraction has been developed for extraction of fifteen organic sulphur compounds from aqueous samples. The analysis of the extracted them was performed by gas chromatography equipped with mass spectrometry and/or flame photometric detectors. 3.3 µL of organic solvent located in the lumen of hollow fibre was used to extract OSCs from an 8 mL of aqueous sample. Several parameters influencing extraction efficiency such as salt concentration, stirring speed, temperature, sample volume, organic phase volume and extraction time were studied and optimized using super-modified simplex method. Under optimized conditions, including extraction solvent (toluene) extraction time (15 min ), salt addition (4 % w/v), stirring rate (1200 rpm), sample volume (8 ml SV), organic solvent volume (3.3 µl) and extraction temperature (35oC), the limits of detection varied from 0.1 to 8.7 µg/L and 0.7 to 99.4 µg/L for GC-FPD and GC-MS, respectively. The calibration graphs were linear over three orders of magnitude for most of the studied OSCs. The relative standard deviations for inter- and intra-day analysis were in the range of 5 to 10%, and the relative recoveries of the analytes from the three different real water samples were more than 83%. The results were compared with those obtained using direct single drop micro-extraction and headspace single drop micro- methods. The proposed method is reliable and can be considered useful for routine monitoring of the organic sulphur compounds in surface water samples.
    کلید واژگان
    Hollow Fiber
    Liquid-phase micro-extraction
    Organic sulfur

    شماره نشریه
    1
    تاریخ نشر
    2020-01-01
    1398-10-11
    ناشر
    Iranian Chemical Society
    سازمان پدید آورنده
    Department of Chemistry, Islamic Azad University, South Tehran Branch, Tehran
    Islamic Azad University, North Tehran Branch, Tehran

    شاپا
    2383-093X
    URI
    https://dx.doi.org/10.22036/abcr.2019.161588.1292
    http://www.analchemres.org/article_89935.html
    https://iranjournals.nlai.ir/handle/123456789/99350

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب