    Development and Validation of an Ion Chromatography Method for Quantification of Ammonium Ions in STEALTH® Liposomes

    (ندگان)پدیدآور
    Arvand, MajidNickdoust Masouleh, AfshinJalilzadeh Moghimi, Seyyed Mohammad
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    910.6کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Research Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Ammonium sulfate is one of the subsidiary components in the stealth liposome structure. The ratio of ammonium ion bound to liposome sphere to ammonium ions outside the liposome plays an important role in drug delivery formulation; accordingly, in order to quantify the ammonium ion in the liposome structure, a rapid and sensitive method was validated using a conductivity detector. Through this method, the amount of ammonium enclosed in the liposomal spheres is determined by subtracting the amount of extra-liposomal ammonium content from the total amount of ammonium present in the liposome structure. Destruction of the liposome structure with the aid of 1% w/w Triton-X-100 solution allows for the analysis of the total ammonium ion present in the liposome structure. In the present research, ultrafiltration made it possible to isolate and analyze the extra-liposomal ammonium ions. This measurement was performed using an ion exchange chromatography column, isocratic elution flow and a linearity of 0.9998. Based on this signal-to-noise method, LOD was determined as 0.0003 mmol/L ammonium ion, with a signal-to-noise ratio of 3:1 and RSD was 1.4%. With a signal-to-noise ratio of 10:1, LOQ was determined as 0.001 mmol/L ammonium ion with RSD 1.2%. In the determination of the total ammonium ion, the individual percentage recovery ranged from 100.00 to 100.93% and for the external ammonium ion analysis, the individual percentage recovery varied from 95.87 to 98.12% for all three levels and RSDs are 0.27, 0.71, and 0.71% for these concentrations.
    کلید واژگان
    Stealth liposome
    Drug Delivery
    Lysing agent
    Ultrafiltration

    شماره نشریه
    1
    تاریخ نشر
    2020-01-01
    1398-10-11
    ناشر
    Iranian Chemical Society
    سازمان پدید آورنده
    Department of Chemistry, Faculty of Science, University of Guilan, Namjoo Street, P.O. Box 1914, Rasht, Iran
    Department of Chemistry, Pardis Campus, University of Guilan, Park-e-Shahr, Rasht, Iran
    Sobhan Oncology Co. No. 11, 5th Alley, Bucharest Ave., Argentina Sq, Tehran, Iran

    شاپا
    2383-093X
    URI
    https://dx.doi.org/10.22036/abcr.2019.160759.1289
    http://www.analchemres.org/article_89888.html
    https://iranjournals.nlai.ir/handle/123456789/99349

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب