• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Analytical and Bioanalytical Chemistry Research
    • Volume 2, Issue 1
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Analytical and Bioanalytical Chemistry Research
    • Volume 2, Issue 1
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    A New Dispersive Liquid-Liquid Microextraction Method Followed by Direct GF-AAS Determination Optimized with Experimental Design and Response Surface Methodology for Determination of Ag(I) in Water Samples

    (ندگان)پدیدآور
    Ghiasvand, AlirezaShadabi, ShahriarHajipour, SomayehNasirian, Afagh
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    353.6کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Research Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    In this research, a rapid, reliable and selective dispersive liquid-liquid microextraction (DLLME) followed by direct injection of microdroplet to graphite furnace atomic absorption spectrometry (GF-AAS) method for the determination of ultra-trace amounts of Ag(I) was developed. Effect of the important experimental parameters on the extraction efficiency of Ag(I) was investigated using response surface methodology (RSM) by performing a central composite design (CCD). A newly synthesized Calixarene (mesotetraspirocyclohexylcalix[4]pyrrole, TSCC4P) was utilized as the chelating agent. The optimal experimental condition was obtained as sample volume: 5 ml, dispersive solvent type: methanol, dispersive solvent volume: 715 μl, extracting solvent: 1,2-dichlorobenzene, volume of extracting solvent: 25 µl, amount of TSCC4P: 127.1 µg, and pH of sample solution: 6.5. Under the optimum conditions Ag(I) ions were extracted into a fine sedimented microdroplet, which 10 µl of it was directly injected into GF-AAS system. The calibration graph was linear over the range of 0.1-10.0 ng ml-1 with a detection limit (S/N = 3) of 0.02 ng ml-1. The relative standard deviation (RSD%) for ten replicated determinations of 10 ng ml-1 Ag(I) was 3.1%. The enrichment factor and extraction recovery were found to be 292 and 96%, respectively. The proposed DLLME-GF-AAS method was successfully applied to the extraction and determination of Ag(I) ions in different real water samples.
    کلید واژگان
    Silver
    Dispersive liquid-liquid microextraction
    GF-AAS
    Experimental Design
    Response Surface Methodology

    شماره نشریه
    1
    تاریخ نشر
    2015-06-01
    1394-03-11
    ناشر
    Iranian Chemical Society
    سازمان پدید آورنده
    Department of Chemistry, Lorestan University, Khoramabad, Iran
    Department of Chemistry, Lorestan University, Khoramabad, Iran
    Department of Chemistry, Lorestan University, Khoramabad, Iran
    1-Department of Chemistry, Lorestan University, Khoramabad, Iran 2-Department of Chemistry, Faculty of Basic Science, Islamic Azad University, Shahreza, Iran

    شاپا
    2383-093X
    URI
    https://dx.doi.org/10.22036/abcr.2015.9817
    http://www.analchemres.org/article_9817.html
    https://iranjournals.nlai.ir/handle/123456789/99289

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب