      Three Dimensional Quality Assessments of Applied Pelvic Binders

      (ندگان)پدیدآور
      Bakhshayesh, PeymanHullberg Risling, DavidEnocson, Anders
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      987.4کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Article
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Objective: To assess the quality of applied pelvic binders using three dimensional computer tomography (3D CT).Methods: A local trauma registry was used to identify patients with pelvic fractures after high-energy trauma during 2011-2015. A 3D CT reconstruction was made from the initial trauma computer tomography images to assess the level of application, symmetricity of the binder and achieved fracture reduction. An acceptable application of the pelvic binder was deemed if it was at the trochanteric level, symmetric and minimized residual displacement.Results:  We found 73 patients with a pelvic fracture and a pelvic binder on the initial trauma CT-scan. The mean (±SD) age of the patients was 46±17 years and 40% (n=29) were females. The median ISS score was 38 (IQR;29-50), the mean systolic blood pressure on arrival was 106±46 mmHg and the median GCS on arrival was 14 (IQR;7-15). We found that 59% (n=43) of the binders were correctly applied (symmetric at the trochanteric level, symmetrical and with acceptable residual displacement of the fracture). The 30-day mortality was higher in patients with non-correct application 17% (n=5/30) compared to patients with correct application of the pelvic binder 9.3% (n=4/43) however this was not statistically significant (p=0.562).Conclusion: A substantial number of patients had non-correct application of pelvic binders. Future studies using 3D technique are encouraged to further investigate clinical impacts of non-appropriate application of pelvic binders.
      کلید واژگان
      Pelvic binder
      Pelvic trauma
      Resuscitation
      Hospital length of stay
      3D CT scan

      شماره نشریه
      2
      تاریخ نشر
      2019-04-01
      1398-01-12
      ناشر
      Shiraz University of Medical Sciences
      سازمان پدید آورنده
      Karolinska Institute

      شاپا
      2322-2522
      2322-3960
      URI
      https://dx.doi.org/10.29252/beat-070211
      https://beat.sums.ac.ir/article_45347.html
      https://iranjournals.nlai.ir/handle/123456789/97082

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب