• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Bulletin of Emergency And Trauma
    • Volume 7, Issue 2
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Bulletin of Emergency And Trauma
    • Volume 7, Issue 2
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Effects of Epidural Needle Rotation on Evolution of Unilateral Epidural Block and Patients’ Hemodynamics beside Recovery Profile in Patients Undergoing Arthroscopic Knee Surgeries; A Randomized Clinical Trial

    (ندگان)پدیدآور
    Hosseini, BehnamMosaffa, FaramarzDabir, ShidehTanghatari, HamedTaheri, Mehrdad
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.482 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Objective: To evaluate the evolution pattern of epidural block after rotating the needle tip 45° to the operative side and evaluate its effects on patients' hemodynamics and recovery profile in those undergoing arthroscopic knee surgery.Methods: Forty participants were randomly subdivided into control and rotation group (n=20). An 18-gauge, 3.5 inch, Tuohy needle was placed at the level of L4-5 and pushed forward into the epidural space through parasagittal approach, in control group, the needle was pushed forward to the epidural space in cephaldad 90 degrees. For the rotation group, the needle was pushed forward to the epidural space and the tip was rotated 45 degrees to the surgical side.15 mL of bupivacaine 0.5% was injected and evolution of sensory and motor blocks until 2-segment regression of the sensory level below to T10 as well as total duration of motor block and surgery were recorded. Hemodynamic parameters (HR, MAP, and SPO2), hypotension, fluid intake, vasopressors, first ambulation and spontaneous urination were recorded. Statistical analysis was performed using SPSS and P≤0.5 considered significant.Results: Sensory block up to T10 level, Complete motor block and time for 2-segment regression of sensory level were earlier in the 45°-rotation than in the control group (p
    کلید واژگان
    Epidural anesthesia
    Hemodynamic
    Block evolution
    Recovery profile
    Needle rotation

    شماره نشریه
    2
    تاریخ نشر
    2019-04-01
    1398-01-12
    ناشر
    Shiraz University of Medical Sciences

    شاپا
    2322-2522
    2322-3960
    URI
    https://dx.doi.org/10.29252/beat-070207
    https://beat.sums.ac.ir/article_45343.html
    https://iranjournals.nlai.ir/handle/123456789/97078

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب