      Correlation of Blood Gas Parameters with Central Venous Pressure in Patients with Septic Shock; a Pilot Study

      (ندگان)پدیدآور
      Baratloo, AlirezaRahmati, FarhadRouhipour, AlalehMotamedi, MaryamGheytanchi, ElmiraAmini, FaribaSafari, Saeed
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      729.8کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      ABSTRACTObjective: To determine the correlation between blood gas parameters and central venous pressure (CVP) in patients suffering from septic shock.Methods: Forty adult patients with diagnosis of septic shock who were admitted to the emergency department (ED) of Shohadaye Tajrish Hospital affiliated with Shahid Beheshti University of Medical Sciences, and met inclusion and exclusion criteria were enrolled. For all patients, sampling was done for venous blood gas analysis, serum sodium and chlorine levels. At the time of sampling; blood pressure, pulse rate and CVP were recorded. Correlation between blood gas parameters and hemodynamic indices were.Results: A significant direct correlation between CVP with anion gap (AG) and inversely with base deficit (BD) and bicarbonate. CVP also showed a relative correlation with pH, whereas it was not correlated with BD/AG ratio and serum chlorine level. There was no significant association between CVP and clinical parameters including shock index (SI) and mean arterial pressure (MAP).Conclusion: It seems that some of non invasive blood gas parameters could be served as alternative to invasive measures such as CVP in treatment planning of patients referred to an ED with septic shock.
      کلید واژگان
      Septic shock
      Central venous pressure
      Noninvasive monitoring

      شماره نشریه
      2
      تاریخ نشر
      2014-04-01
      1393-01-12
      ناشر
      Shiraz University of Medical Sciences

      شاپا
      2322-2522
      2322-3960
      URI
      https://beat.sums.ac.ir/article_44253.html
      https://iranjournals.nlai.ir/handle/123456789/97022

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب