      Comparative performance assessment of flat plate and evacuated tube collectors for domestic water heating systems in Kerman, Iran

      (ندگان)پدیدآور
      Farzan, Hadi
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      1.057 مگابایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Research Paper
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      This study represents a year-round energy performance of two solar water heating (SWH) systems with a 4m2 flat plate collector (FPC) and an evacuated tube collector (ETC) operating under the same weather conditions. The energy performance of the two considered systems was compared on a monthly and yearly basis. The obtained results showed that for an annual total solar insolation of 2056kW.h.m-2, a total of 3577kW.h.y-1 and 4201kW.h.y-1 of heat energy were collected by 4m2 FPC and, ETC systems, respectively. The annual average energy efficiency by the FPC system was 43%, while its annual solar fraction was 50%. The ETC system had 51% energy efficiency with 58% solar fraction. The economic analysis showed that both solar water heating systems are not economically viable under prevailing costs in Iran. Furthermore, according to the obtained results, the FPCs are more favorable than the ETCs due to its economic analysis and energy performance. These results provide useful information for households and policymakers.
      کلید واژگان
      Plat Plate Collector
      Evacuated Tube Collector
      Energy Performance Analysis
      Economic Analysis
      Solar Water Heater

      شماره نشریه
      2
      تاریخ نشر
      2020-06-01
      1399-03-12
      ناشر
      University of Tehran
      سازمان پدید آورنده
      Mechanical Engineering Department, Engineering Faculty, Higher Education Complex of Bam, Bam, Iran

      شاپا
      2383-1111
      2345-251X
      URI
      https://dx.doi.org/10.22059/ees.2020.43226
      http://www.energyequipsys.com/article_43226.html
      https://iranjournals.nlai.ir/handle/123456789/95218

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب