• ورود به سامانه
      مشاهده مورد 
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Energy Equipment and Systems
      • Volume 6, Issue 4
      • مشاهده مورد
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Energy Equipment and Systems
      • Volume 6, Issue 4
      • مشاهده مورد
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      Thermoeconomic analysis of a hybrid PVT solar system integrated with double effect absorption chiller for cooling/hydrogen production

      (ندگان)پدیدآور
      Behzadi, AmirmohammadGholamian, EhsanHoushfar, EhsanAshjaee, MehdiHabibollahzade, Ali
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      1.181 مگابایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Research Paper
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      A novel solar-based combined system which is consisting of a concentrated PV, a double effect LiBr-H2O absorption chiller, and a Proton Exchange Membrane (PEM) is proposed for hydrogen production. A portion of the received energy is recovered to run a double effect absorption chiller and the rest is turned into electricity, being consumed in the PEM electrolyzer for hydrogen production. The thermodynamic and thermoeconomic analyses are performed to understand the system performance. A parametric study which is implementing Engineering Equation Solver (EES) is carried out to assess the influence of main decision parameters on the overall exergy efficiency and total product unit cost. The 2nd law analysis shows that PVT with exergy destruction rate of 76.9% of total destruction rate is the major source of irreversibility. Furthermore, in the cooling system, Cooling Set (CS) has the highest exergy destruction rate due to the dissipative components. Exergoeconomic results demonstrate that in cooling set with the lowest value of exergoeconomic factor, the cost of exergy destruction and loss has the major effect on the overall cost rate. Furthermore, results of the parametric study indicate that by decreasing PV cell's temperature from 100 °C to 160 °C, the total product unit cost is decreased by about 1.94 $/GJ.
      کلید واژگان
      PVT
      Cogeneration
      Exergoeconomic
      Double Effect LiBr-H2O
      PEM

      شماره نشریه
      4
      تاریخ نشر
      2018-12-01
      1397-09-10
      ناشر
      University of Tehran
      سازمان پدید آورنده
      School of Mechanical Engineering, College of Engineering, University of Tehran, P.O. Box 11155-4563, Tehran, Iran
      School of Mechanical Engineering, College of Engineering, University of Tehran, P.O. Box 11155-4563, Tehran, Iran
      School of Mechanical Engineering, College of Engineering, University of Tehran, P.O. Box 11155-4563, Tehran, Iran
      School of Mechanical Engineering, College of Engineering, University of Tehran, P.O. Box 11155-4563, Tehran, Iran
      School of Mechanical Engineering, College of Engineering, University of Tehran, P.O. Box 11155-4563, Tehran, Iran

      شاپا
      2383-1111
      2345-251X
      URI
      https://dx.doi.org/10.22059/ees.2018.33319
      http://www.energyequipsys.com/article_33319.html
      https://iranjournals.nlai.ir/handle/123456789/95203

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب