    Thermoeconomic analysis of a hybrid PVT solar system integrated with double effect absorption chiller for cooling/hydrogen production

    (ندگان)پدیدآور
    Behzadi, AmirmohammadGholamian, EhsanHoushfar, EhsanAshjaee, MehdiHabibollahzade, Ali
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.181 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Research Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    A novel solar-based combined system which is consisting of a concentrated PV, a double effect LiBr-H2O absorption chiller, and a Proton Exchange Membrane (PEM) is proposed for hydrogen production. A portion of the received energy is recovered to run a double effect absorption chiller and the rest is turned into electricity, being consumed in the PEM electrolyzer for hydrogen production. The thermodynamic and thermoeconomic analyses are performed to understand the system performance. A parametric study which is implementing Engineering Equation Solver (EES) is carried out to assess the influence of main decision parameters on the overall exergy efficiency and total product unit cost. The 2nd law analysis shows that PVT with exergy destruction rate of 76.9% of total destruction rate is the major source of irreversibility. Furthermore, in the cooling system, Cooling Set (CS) has the highest exergy destruction rate due to the dissipative components. Exergoeconomic results demonstrate that in cooling set with the lowest value of exergoeconomic factor, the cost of exergy destruction and loss has the major effect on the overall cost rate. Furthermore, results of the parametric study indicate that by decreasing PV cell's temperature from 100 °C to 160 °C, the total product unit cost is decreased by about 1.94 $/GJ.
    کلید واژگان
    PVT
    Cogeneration
    Exergoeconomic
    Double Effect LiBr-H2O
    PEM

    شماره نشریه
    4
    تاریخ نشر
    2018-12-01
    1397-09-10
    ناشر
    University of Tehran
    سازمان پدید آورنده
    School of Mechanical Engineering, College of Engineering, University of Tehran, P.O. Box 11155-4563, Tehran, Iran
    School of Mechanical Engineering, College of Engineering, University of Tehran, P.O. Box 11155-4563, Tehran, Iran
    School of Mechanical Engineering, College of Engineering, University of Tehran, P.O. Box 11155-4563, Tehran, Iran
    School of Mechanical Engineering, College of Engineering, University of Tehran, P.O. Box 11155-4563, Tehran, Iran
    School of Mechanical Engineering, College of Engineering, University of Tehran, P.O. Box 11155-4563, Tehran, Iran

    شاپا
    2383-1111
    2345-251X
    URI
    https://dx.doi.org/10.22059/ees.2018.33319
    http://www.energyequipsys.com/article_33319.html
    https://iranjournals.nlai.ir/handle/123456789/95203

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب