      The development and assessment of solar-driven Tri-generation system energy and optimization of criteria comparison

      (ندگان)پدیدآور
      Ghasemkhani, AmirFarahat, SaidNaserian, Mohammad Mahdi
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      1.553 مگابایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      In this research, the thermodynamic investigation of the tri-generation system is performed by the first and second law of Thermodynamics. The trigeneration system under study consists of three subsystems including the solar subsystem, Kalina subsystem and lithium bromide-water absorption chiller subsystem. The proposed system generates power, cooling and hot water using solar energy. The system considered is designed and evaluated based on the climate condition in Zahedan, Iran. The calculation results show that the most exergy destruction rate takes place in the solar cycle. The assessment of system is used dynamic and static forms. In dynamic form, that maximum total cost rate, energy and exergy efficiency are equal to 15.1 dollars per hour,by 33% and 36.47%, respectively. The results base-case demonstrate that energy and exergy efficiencies and total cost rates are equal to 9.63 dollars per hour by 17.37% and 18.82% , respectively in static analysis. Furthermore, optimization criteria comparison such as energy efficiency, exergy efficiency and power are discussed in static form. The results of static evaluation revealed that the power is the best criteria for thermodynamics. Moreover, optimization results based on maximum power criterion show that produced power, energy efficiency, exergy efficiency and total cost rate increase by 28%, 12.32%, of 13.97% and 7.68%, respectively in comparison with the base case.
      کلید واژگان
      Energy Analysis
      Exergy Analysis
      Parabolic Trough Solar Collector
      Trigeneration
      Solar Energy

      شماره نشریه
      4
      تاریخ نشر
      2018-12-01
      1397-09-10
      ناشر
      University of Tehran
      سازمان پدید آورنده
      Department of Mechanical Engineering, Faculty of Engineering, University of Sistan and Bluchestan, Zahedan, Iran
      Department of Mechanical Engineering, Faculty of Engineering, University of Sistan and Bluchestan, Zahedan, Iran
      Department of Mechanical Engineering, Faculty of Engineering, University of Sistan and Bluchestan, Zahedan, Iran

      شاپا
      2383-1111
      2345-251X
      URI
      https://dx.doi.org/10.22059/ees.2018.33309
      http://www.energyequipsys.com/article_33309.html
      https://iranjournals.nlai.ir/handle/123456789/95200

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب