      Exergy, exergoeconomic and exergoenvironmental studies and optimization of a novel triple-evaporator refrigeration cycle with dual-nozzle ejector using low GWP refrigerants

      (ندگان)پدیدآور
      Nazer, SaharAhmadi Boyaghchi, Fateme
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      2.370 مگابایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Research Paper
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      In this work, a novel dual-nozzle ejector enhanced triple-evaporator refrigeration cycle (DETRC) without separator is proposed to improve the performance of the conventional ejector one (CETRC). The performance of DETRC is analyzed and compared with CETRC in term of energy coefficient of performance (COPen). Under given operating conditions, the COPen improvement of the novel cycle could reach about 24.35% which shows the excellent energy-saving potential of DETRC in comparison with CETRC. Then, a comprehensive comparison between R717, R600a, R1234yf and R290 as low global warming potential (GWP) refrigerants of DETRC is conducted from the energy, exergy, economic and environmental impact (EI) aspects. It is observed that R717 gives better energetic and exergetic performances by 3.21 and 0.583 and R1234yf causes the lowest total product cost and EI rates of 8.186 $/h and 0.665 Pts/h, respectively for DETRC. Moreover, increasing the high evaporating temperature improves all desired performances of DETRC, simultaneously due to the reduction of compressor consumed power. Finally, a multi-objective optimization based on an evolutionary algorithm and LINMAP decision making are carried out to ascertain the optimum exergetic, economic and EI performances of DETRC for each refrigerant.
      کلید واژگان
      Dual-Nozzle Ejector
      Triple-Evaporator
      Exergoeconomic Analysis
      Exergoenvironmental Analysis
      Optimization

      شماره نشریه
      1
      تاریخ نشر
      2020-03-01
      1398-12-11
      ناشر
      University of Tehran
      سازمان پدید آورنده
      Department of Mechanical Engineering, Faculty of Engineering & Technology, Alzahra University, Deh-Vanak, Tehran, Iran
      Department of Mechanical Engineering, Faculty of Engineering & Technology, Alzahra University, Deh-Vanak, Tehran, Iran

      شاپا
      2383-1111
      2345-251X
      URI
      https://dx.doi.org/10.22059/ees.2020.39009
      http://www.energyequipsys.com/article_39009.html
      https://iranjournals.nlai.ir/handle/123456789/95100

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب