      Improving the performance of wind turbine equipped with DFIG using STATCOM based on input-output feedback linearization controller

      (ندگان)پدیدآور
      Shahgholian, GhazanfarIzadpanahi, Noushaz
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      1.521 مگابایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Research Paper
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Using the FACTS controllers, such as static synchronous compensator (STATCOM), as it provides continuous reactive power, in the grid including wind turbine (WT) equipped with doubly fed induction generator, for improving voltage profile (under normal circumstances) and providing a transition ability from inductor generator transition state has been proposed. In this paper, in order to control the controllers and explained goals, nonlinear controller, as a substitute for the traditional controller, is presented. Replacing STATCOM controller in wind farm, which is equipped with doubly fed induction generator (DFIG) using input-output feedback linearization controller, the needed reactive power in order to stable wind farm equipped with DFIG is considered when error is occurred. The proposed control method has been simulated for IEEE-9 Bus, bus No 5, and the achievability to the desired targets in STATCOM efficiency for its reactive power has been investigated. The reasons of using these controllers in bus 5 are voltage dropping and reducing reactive power in this bus. It can be seen by compensating for voltage and reactive power in this bus that these two parameters have improved in other buses. The results show that with the proposed controller, STATCOM has done its duty well and the network bus voltage and reactive power to sustain the wind farm equipped with DFIG in transient mode is provided.
      کلید واژگان
      Doubly Fed Induction Generator
      Static Synchronous Compensator
      Transition State
      Wind Farm
      Input-Output Feedback Linearization Controller

      شماره نشریه
      1
      تاریخ نشر
      2016-06-01
      1395-03-12
      ناشر
      University of Tehran
      سازمان پدید آورنده
      Islamic Azad University, Isfahan, Iran
      Islamic Azad University, Isfahan, Iran

      شاپا
      2383-1111
      2345-251X
      URI
      https://dx.doi.org/10.22059/ees.2016.20128
      http://www.energyequipsys.com/article_20128.html
      https://iranjournals.nlai.ir/handle/123456789/95074

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب