Evaluation of Parameters Influencing Hexavalent Chromium Mist Sampling: A Full Factorial Design
(ندگان)پدیدآور
Tirgar, AramGolbabaei, FaridehNourijelyani, KeramatAkbar Kanzadeh, FarhangShahtaheri,, Sayed JamaleddinGanjali, Mohammad RezaHamedi, Javadنوع مدرک
TextResearch Note
زبان مدرک
Englishچکیده
A chromium electroplating bath with the ability to produce homogenous mist was used to evaluate parameters influencing hexavalent chromium (Cr+6) mist sampling methods. The results of 48 Cr+6mist samples collected using the U.S. National Institute for Occupational Safety and Health method 7600showed that Cr+6concentration was higher: (1) For sampling by closed-face filter cassettes than for sampling by open-face filter cassettes (P It is concluded that the accuracy of Cr+6 mist sampling in electroplating shops will be enhanced when: (1) closed-face filter cassette is used to prevent liquid splash contamination; (2) the recommended sampling height is 35 cm above the solution surface; (3) the sampling duration is short--approximately 30 minutes; and, (4) the extraction of the Cr+6 sample is performed as soon as the sampling is completed.
کلید واژگان
Hexavalent chromiumMist
electroplating
Chromium sampling method
Sampling head
Sampling duration
Storage duration
Sampling height
Applied Chemistry
Inorganic Chemistry
شماره نشریه
4تاریخ نشر
2007-12-011386-09-10
ناشر
Iranian Institute of Research and Development in Chemical Industries (IRDCI)-ACECRسازمان پدید آورنده
School of Public Health, Medical Sciences / University of Tehran, Tehran, I.R. IRANSchool of Public Health, Medical Sciences / University of Tehran, Tehran, I.R. IRAN
School of Public Health, Medical Sciences / University of Tehran, Tehran, I.R. IRAN
Medical University of Ohio at Toledo, P.O. Box 43614 Ohio, U.S.A
School of Public Health, Center for Environmental Research, Medical Sciences / University of Tehran, Tehran, I.R. IRAN
School of Chemistry, University of Tehran, P.O. Box 14155-8464 Tehran, I.R. IRAN
School of Chemistry, University of Tehran, P.O. Box 14155-8464 Tehran, I.R. IRAN
شاپا
1021-9986Related items
Showing items related by title, author, creator and subject.
-
Performance of HPV Self-Sample Collected by a Novel Kit in Comparison with Clinician Collected Sample for Cervical Cancer Screening
Joshi, Smita؛ Kumar, B Kishore؛ Ramshankar, Vijayalakshmi؛ Maitra, Nandita؛ Palit, Sayantani؛ Ravindran, Soundharya؛ Shyam, Twinkle (West Asia Organization for Cancer Prevention (WAOCP), 2024-12-01)Background and Objectives: We are reporting the performance of HPV self-sample collected by a novel kit in comparison with clinician collected cervical sample for HPV testing for cervical cancer screening. Methods: Consenting, ...
-
Sample Size Calculation Guide - Part 7: How to Calculate the Sample Size Based on a Correlation
Ahmed Negida (Tehran University of Medical Sciences, 2020-03-22)In the previous educational articles, we explained how to calculate the sample size for a rate or a single proportion, for an independent cohort study, for an independent case-control study, for a diagnostic test accuracy ...
-
Application of adaptive sampling in fishery part 2: Truncated adaptive cluster sampling designs
Salehi, M. (Tehran, Institute of Fisheries Science of Iran, 2001-01-01)There are some experiences that researcher come across quite number of time for very large networks in the initial samples such that they cannot finish the sampling procedure. Two solutions have been proposed and used by ...