      Experimental Investigation on Hydrodynamic and Thermal Performance of a Gas-Liquid Thermosyphon Heat Exchanger in a Pilot Plant

      (ندگان)پدیدآور
      Zare Aliabadi, HassanAtashi, HosseinNoie, Seyed HosseinKhoshnoodi, Mohammad
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      535.9کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Research Article
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Waste heat recovery is very important, because not only it reduces the expenditure of heat generation, but also it is of high priority in environmental consideration, such as reduction in greenhouse gases. One of the devices is used in waste heat recovery is heat pipe heat exchanger.Anexperimental research has been carried out to investigate the hydrodynamic and thermal performance of a gas- liquid thermosyphon heat exchanger “THE" in a pilot plant. The ε-NTU method has been used. The pressure drop has been calculated across tube bundle of the thermosyphon heat exchanger. It's module is composed of 6 “rows" and 15 “columns" copper pipes with aluminum plate fins with dimensions of 130 cm “height", 47 cm “width" and  20 cm “depth" . The tubes have been filled by water with filling ratio of 30 %, 50 % and 70 %. The density and thickness of fins are 300 fin/m and 0.4 mm, respectively. The configuration of tubes is in-line with 30 mm pitch. The results show that as the ratio of Ce/Cc raises the amount of heat transfer increases. The effectiveness of heat pipe heat exchanger remains constant as the temperature of hot stream rises, but the amount of heat transfer increases. Filling ratio in normal region (30-70 %) has no effects on experimental results. A new correlation for thermosyphon heat exchanger with individual finned tubes and in-line geometry has been proposed for calculating pressure drop across tube bank of a “THE". The error in pressure drop for 40 experimental points in the new correlation is less than 15 %. This indicates that the new correlation possesses an acceptable accuracy predicting pressure drop.
      کلید واژگان
      Thermosyphon heat exchanger "THE"
      ε-NTU method
      in-line configuration
      Pressure drop
      Finned tube bundle
      Fluid Mechanics, CFD

      شماره نشریه
      3
      تاریخ نشر
      2008-09-01
      1387-06-11
      ناشر
      Iranian Institute of Research and Development in Chemical Industries (IRDCI)-ACECR
      سازمان پدید آورنده
      Department of Chemical Engineering, University of Sistan and Baluchestan, Zahedan, I.R. IRAN
      Department of Chemical Engineering, University of Sistan and Baluchestan, Zahedan, I.R. IRAN
      Department of Chemical Engineering, Ferdowsi University of Mashhad, Mashhad, I.R. IRAN
      Department of Chemical Engineering, University of Sistan and Baluchestan, Zahedan, I.R. IRAN

      شاپا
      1021-9986
      URI
      http://www.ijcce.ac.ir/article_6975.html
      https://iranjournals.nlai.ir/handle/123456789/84003

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب