• ورود به سامانه
      مشاهده مورد 
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • International Journal of Nano Dimension
      • Volume 7, Issue 1
      • مشاهده مورد
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • International Journal of Nano Dimension
      • Volume 7, Issue 1
      • مشاهده مورد
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      Sensitivity analysis of a caliper formed atomic force microscope cantilever based on a modified couple stress theory

      (ندگان)پدیدآور
      Abbasi, M.Abbasi, N.
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      392.1کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Reasearch Paper
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      A relationship based on the modified couple stress theory is developed to investigate the flexural sensitivity of an atomic force microscope (AFM) with assembled cantilever probe (ACP). This ACP comprises a horizontal cantilever, two vertical extensions and two tips located at the free ends of the extensions which form a caliper. An approximate solution to the flexural vibration problem is obtained using the Rayleigh–Ritz method. The results show that the sensitivities of AFM ACP obtained by the modified couple stress theory are smaller than those evaluated by the classical beam theory at the lower contact stiffness. The results also indicate that the flexural sensitivities of the proposed ACP are strong size dependant when the thickness of the cantilever is close to the material length scale, especially at lower contact stiffness. Furthermore, the greatest flexural modal sensitivity occurs at a small contact stiffness of the system, in which the ratio of the cantilever thickness to the material length scale and the distance between the vertical extensions are also small. In this situation, the distance between the vertical extensions and the clamped end of the cantilever and also the vertical extensions lengths are large. The results reveal that the sensitivity of the right sidewall tip is higher than that of the left one.
      کلید واژگان
      Assembled cantilever probe
      Atomic force microscope
      Modified couple stress theory
      Rayleigh–Ritz method
      size dependent
      Microscopy Analysis
      Nanotechnology

      شماره نشریه
      1
      تاریخ نشر
      2016-01-01
      1394-10-11
      ناشر
      Islamic Azad University-Tonekabon Branch
      سازمان پدید آورنده
      School of Mechanical Engineering, Shahrood Branch, Islamic Azad University, Shahrood, Iran
      Medicine Department, Tehran University of Medical Science, Tehran, Iran

      شاپا
      2008-8868
      2228-5059
      URI
      https://dx.doi.org/10.7508/ijnd.2016.01.006
      http://www.ijnd.ir/article_644315.html
      https://iranjournals.nlai.ir/handle/123456789/80280

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب