نمایش مختصر رکورد

dc.contributor.authorsharafi, alien_US
dc.contributor.authorkheiri, Hamidrezaen_US
dc.contributor.authorbijani, soroushen_US
dc.contributor.authorahmadnia, Alirezaen_US
dc.contributor.authordanafar, hosseinen_US
dc.date.accessioned1399-07-08T20:00:40Zfa_IR
dc.date.accessioned2020-09-29T20:00:40Z
dc.date.available1399-07-08T20:00:40Zfa_IR
dc.date.available2020-09-29T20:00:40Z
dc.date.issued2016-04-01en_US
dc.date.issued1395-01-13fa_IR
dc.date.submitted2016-06-18en_US
dc.date.submitted1395-03-29fa_IR
dc.identifier.citationsharafi, ali, kheiri, Hamidreza, bijani, soroush, ahmadnia, Alireza, danafar, hossein. (2016). Simple and sensitive high performance liquid chromatographic (HPLC) method for the determination of the apigenin from dried powder of Cosmos bipinnatus, Apium graveolens and Petroselinum crispum. Iranian Journal of Pharmaceutical Sciences, 12(2), 21-32. doi: 10.22034/ijps.2016.22799en_US
dc.identifier.issn1735-2444
dc.identifier.urihttps://dx.doi.org/10.22034/ijps.2016.22799
dc.identifier.urihttp://www.ijps.ir/article_22799.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/79241
dc.description.abstractApigenin is best known as an irreversible inhibitor of monoamine oxidase (MAO), an intracellular enzyme associated with the outer membrane of mitochondria. The purpose of this study is to establish a reliable and quick method for the assignment of Apigenin in Cosmos bipinnatus, Apium graveolens and Petroselinum crispum by high performance liquid chromatography with ultraviolet detection (HPLC-UV). A rapid and sensitive high performance liquid chromatographic (HPLC) method has been developed for determination of Apigenin in human apigenin. Mobile phase was composed water-acetonitrile (55:45 v/v) with a flow rate of 1 ml/min. The eluted peaks were detected by a UV detector was set at wavelength of 340 nm. The method was validated in the range of Apigenin concentrations from 0.01 to 500 µg/ml. The limits of detection (LOD) and quantitation (LOQ) of the method were 0.005 and 0.01 µg/ml, respectively. The average recovery was 97.28 percent throughout the linear concentration range. The average within-run and between-run accuracy values of 99.32 and 96.79 respectively. The method is quick, simple, sensitive and precise for the screen, assignment, and evaluation of Apigenin in plants by HPLC.en_US
dc.format.extent482
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherIranian Association of Pharmaceutical Scientistsen_US
dc.relation.ispartofIranian Journal of Pharmaceutical Sciencesen_US
dc.relation.isversionofhttps://dx.doi.org/10.22034/ijps.2016.22799
dc.subjectApigeninen_US
dc.subjectHPLCen_US
dc.subjectCosmosen_US
dc.subjectbipinnatusen_US
dc.subjectApiumen_US
dc.subjectgraveolensen_US
dc.subjectPetroselinum crispumen_US
dc.subjectNatural productsen_US
dc.titleSimple and sensitive high performance liquid chromatographic (HPLC) method for the determination of the apigenin from dried powder of Cosmos bipinnatus, Apium graveolens and Petroselinum crispumen_US
dc.typeTexten_US
dc.typeResearch Paperen_US
dc.contributor.departmentzanjanen_US
dc.contributor.departmentzanjanen_US
dc.contributor.departmentzanjanen_US
dc.contributor.departmentzanjanen_US
dc.contributor.departmentschool of pharmacy zanjan universityen_US
dc.citation.volume12
dc.citation.issue2
dc.citation.spage21
dc.citation.epage32


فایل‌های این مورد

Thumbnail

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد