• ورود به سامانه
      مشاهده مورد 
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Iranian Journal of Veterinary Surgery
      • Volume 03, Issue 4
      • مشاهده مورد
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Iranian Journal of Veterinary Surgery
      • Volume 03, Issue 4
      • مشاهده مورد
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      Echocardiographic Measurement of Systolic Time Intervals in Healthy Great Dane Dogs

      (ندگان)پدیدآور
      Rajabioun, MasoudVajhi, AlirezaMasoudifard, MajidSelk Ghaffari, MasoudSadeghian, HakimehAzizzadeh, Mohammad
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      232.5کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Article
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Objective- To determine the range of systolic times intervals using Pulsed-wave Doppler and m-mode echocardiography in normal, healthy Great Dane dogs. Design- Descriptive study. Animals- Thirty healthy Great Dane dogs. Procedures- This study examined 30 clinically healthy Great Dane dogs by the two-dimensional, M-mode and Pulsed-wave Doppler echocardiography. The dogs were awake and unsedated. The following parameters were measured on the both Pulsed-wave Doppler and M-mode echocardiographic images: pre-ejection period (PEP), left ventricular ejection time (LVET), ratio of PEP to LVET (PEP/LVET) and the total electrical-mechanical systole (QAVC). Acceleration time of aortic flow (AT) was also measured by Doppler mode. Results- The following values have been acquired: PEP = 0.067 ± 0.010 s; LVET = 0.188 ± 0.011 s; QAVC = 0.254 ± 0.016 s and PEP/LVET = 0.354 ± 0.054 measured by Mmode echocardiography and PEP = 0.062 ± 0.009 s; LVET = 0.193 ± 0.007 s; QAVC = 0.256 ± 0.011s; PEP/LVET = 0.323 ± 0.051 and AT = 0.080 ± 0.107 s measured by Doppler echocardiography. Conclusion and Clinical Relevance- On Doppler mode, there was a significant correlation between the body weight and PEP and PEP/LVET. M-mode echocardiography showed significant correlation between the body weight and body surface area and QAVC. Results of this study revealed the importance of determination of breed-specific echocardiographic parameters and indices, and evaluating of measured values with range using same method for accurate diagnosis.
      کلید واژگان
      echocardiography
      Systolic time intervals
      Great Dane
      M-mode
      Pulsed- wave doppler
      Veterinary Diagnostic Imaging

      شماره نشریه
      4
      تاریخ نشر
      2008-12-01
      1387-09-11
      ناشر
      Iranian Veterinary Surgery Association (IVSA)
      سازمان پدید آورنده
      Department of Clinical Sciences, Faculty of Veterinary Medicine, University of Tehran, Tehran, Iran.
      Department of Clinical Sciences, Faculty of Veterinary Medicine, University of Tehran, Tehran, Iran.
      Department of Clinical Sciences, Faculty of Veterinary Medicine, University of Tehran, Tehran, Iran.
      Department of Clinical Sciences, Faculty of Veterinary Medicine, Islamic Azad University- Karaj Branch, Karaj, Iran.
      Tehran Heart Centre, Faculty of Medical Sciences, Tehran University, Tehran, Iran.
      Department of Clinical Sciences, Faculty of Veterinary Medicine, Ferdowsi University of Mashhad, Mashhad, Iran.

      شاپا
      2008-3033
      2676-6299
      URI
      http://www.ivsajournals.com/article_3166.html
      https://iranjournals.nlai.ir/handle/123456789/71818

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب