      Trace Monitoring of Phthalate Esters in Environmental Water Samples by Ionic Liquid-based Ultrasound-assisted In-situ Solvent Formation Microextraction Combined with High-performance Liquid Chromatography

      (ندگان)پدیدآور
      Zeeb, MohsenFarahani, Hadi
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      397.9کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      A simple and efficient ionic liquid-based ultrasound-assisted in-situ solvent formation microextraction (IL-UA-ISFME) in combination with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) has been gainfully developed for the trace determination of four phthalate esters (PEs) in environmental water samples. In this method, a hydrophobic ionic liquid (1-butyl-3-methylimidazolium hexafluorophosphate) was created by addition of a hydrophilic ionic liquid (1-butyl-3-methylimidazolium tetrafluoroborate) to sample solution constituting an ion-pairing agent (NaPF6). The analytes were extracted inside the ionic liquid phase while the microextraction solvent was dispersed through the sample by utilizing ultrasonic radiation. The sample was then centrifuged and extracting phase retracted into the microsyringe, diluted with acetonitrile, and injected to HPLC. At first, vigorous parameters controlling the performance of the microextraction process were considered and optimized. The limit of detections (LOD, S/N = 3) were in the range of 0.22-0.33 µg L-1 while the RSD% values were below than 6.1% (n = 5). A good linearity (0.996 ≥ r2 ≥ 0.992) and a broad linear over the concentration range from 1.0 to 500 µg L-1 were achieved. At last, the method was applied for the preconcentration and sensitive determination of the PEs in several environmental water samples. The accuracy of the method in the real samples was examined by the relative recovery experiments with results ranging from 90-107%, which approved that intricate matrixes had approximately slight effect on the developed procedure.
      کلید واژگان
      Environmental water samples
      High-performance liquid chromatography
      Ionic liquid
      microextraction
      Phthalate esters

      شماره نشریه
      3
      تاریخ نشر
      2018-09-01
      1397-06-10
      ناشر
      Islamic Azad University, Damghan Branch, Islamic Republic of Iran
      سازمان پدید آورنده
      Department of Applied Chemistry, Faculty of Science, Islamic Azad University, South Tehran Branch, Tehran, Iran
      Research Institute of Petroleum Industry (RIPI), Tehran, Iran

      شاپا
      2251-6719
      2251-6727
      URI
      https://dx.doi.org/10.22034/jchr.2018.544220
      http://www.jchr.org/article_544220.html
      https://iranjournals.nlai.ir/handle/123456789/69952

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب