• ورود به سامانه
      مشاهده مورد 
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Journal of Chemical Health Risks
      • Volume 8, Issue 2
      • مشاهده مورد
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Journal of Chemical Health Risks
      • Volume 8, Issue 2
      • مشاهده مورد
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      Magnetic Solvent Bar Liquid-Phase Microextraction Followed by Gas Chromatography-Flame Ionization Detection for the Trace Determination of Selected Polycyclic Aromatic Hydrocarbons in Environmental Water Samples

      (ندگان)پدیدآور
      Farahani, HadiZeeb, Mohsen
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      661.7کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      A novel and efficient hollow fiber-based method, viz. magnetic solvent bar liquid-phase microextraction (MSB-LPME) combined with gas chromatography-flame ionization detection (GC-FID) was successfully developed for the trace determination of selected polycyclic aromatic hydrocarbons (PAHs) in environmental water samples. The target analytes were extracted from sample solution to the organic solvent immobilized in a fiber. After extraction, the analyte-adsorbed magnetic solvent bar could be readily isolated from the sample solution by a magnet which could greatly simplify the operation and also decline the total pretreatment time. The bar was first eluted with methanol, evaporated to dryness while the residue was dissolved in toluene and finally injected into GC-FID. Begin with, effective parameters controlling the performance of the microextraction were evaluated and optimized. The values of the detection limit of the method were in the range of 0.05-0.08 µg L-1 and the RSD% values for the analysis of 10.0 µg L-1 of the analytes was below than 5.8% (n= 6). A good linearity (0.998 ≥ r2 ≥ 0.994) and a broad linear range (0.1-200 µg L-1) were obtained. The method was eventually utilized for the preconcentration and determination of the PAHs in environmental water samples and satisfactory results were obtained.
      کلید واژگان
      Environmental water samples
      Gas chromatography-flame ionization detection
      Magnetic solvent bar liquid-phase microextraction
      Polycyclic Aromatic Hydrocarbons

      شماره نشریه
      2
      تاریخ نشر
      2018-06-01
      1397-03-11
      ناشر
      Islamic Azad University, Damghan Branch, Islamic Republic of Iran
      سازمان پدید آورنده
      Research Institute of Petroleum Industry (RIPI), Tehran, Iran
      Deptartment of Applied Chemistry, Faculty of Science, Islamic Azad University, South Tehran Branch, Tehran, Iran

      شاپا
      2251-6719
      2251-6727
      URI
      https://dx.doi.org/10.22034/jchr.2018.544208
      http://www.jchr.org/article_544208.html
      https://iranjournals.nlai.ir/handle/123456789/69941