      Electrochemical Evaluation of Hydroxyapatite/ZrN Coated Magnesium Biodegradable Alloy in Ringer Solution as a Simulated Body Fluid

      (ندگان)پدیدآور
      Kiahosseini, Seyed RahimAfshar, AbdollahMojtahedzadeh Larijani, MajidYousefpour, Mardali
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      706.5کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Magnesium alloys as biodegradable materials can be used in body as an implant materials but since they have poor corrosion resistance, it is required to decrease their corrosion rate by biocompatible coatings. In this study, hydroxyapatite (HA) coatings in the presence of an intermediate layer of ZrN as a biocompatible material, deposited on AZ91 magnesium alloy by ion beam sputtering method at 300 °C temperature and at different times 180, 240, 300, 360 and 420 min. Then changes in corrosion resistance of samples in Ringer's solution as a solution similar to the human body was evaluated in two ways, potentiodynamic polarization and electrochemical impedance spectroscopy (EIS). To investigate the causes of the destruction of the samples, the surface of samples was studied by scanning electron microscopy (SEM). The results showed that because of porous coatings created, the corrosion potential of the samples was about +55mV higher than the uncoated substrate that by changing the deposition time, was not observed the significant change But with increasing deposition time to 360 min, corrosion current decreased which represents an increase of corrosion resistance of magnesium alloy in body solution. However, a further increase in deposition time to 420 min, due to increase thickness and stress in the layer, the corrosion resistance of the samples was reduced. The results of the EIS confirm the corrosion behavior of the polarization method, too.  Â
      کلید واژگان
      Biodegradable alloy Corrosion Hydroxyapatite Sputtering

      شماره نشریه
      1
      تاریخ نشر
      2015-02-01
      1393-11-12
      ناشر
      Islamic Azad University, Damghan Branch, Islamic Republic of Iran
      سازمان پدید آورنده
      Department of Materials Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran
      Department of Materials Engineering, Sharif University of Technology, Tehran, Iran
      Agriculture Medical and Industrial Research School, Nuclear Science and Technology Research Institute (NSTRI), Karaj, Iran
      Department of Materials Science and Engineering, Semnan University, Semnan, Iran

      شاپا
      2251-6719
      2251-6727
      URI
      https://dx.doi.org/10.22034/jchr.2018.544092
      http://www.jchr.org/article_544092.html
      https://iranjournals.nlai.ir/handle/123456789/69845