• ورود به سامانه
      مشاهده مورد 
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Journal of Chemical Health Risks
      • Volume 2, Issue 4
      • مشاهده مورد
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Journal of Chemical Health Risks
      • Volume 2, Issue 4
      • مشاهده مورد
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      Separation of Trace Amount Zn (II) Using Additional Carbonyl and Carboxyl Groups Functionalized-Nano Graphene

      (ندگان)پدیدآور
      Moghimi, A.
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      297.0کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      A novel and selective method for the fast determination of trace amounts of Zn(II)ions in water samples has been developed.  The first additional carbonyl and carboxyl functionalized-nano graphene (SPFNano graphene). The presence of additional carbonyl and carboxyl groups located at the edge of the sheets makes GO sheets strongly hydrophilic, allowing them to readily swell and disperse in water. Based on these oxygen functionalities, different model structures of GO were used as absorbent for extraction of Zn (II)   ions by solid phase extraction method. The complexes were eluted with HNO3 (2M)10% V.V-1 methanol in acetone and determined the analyte by flame atomic absorption spectrometry.  The procedure is based on the selective formation of Zn (II) at optimum pH by elution with organic eluents and determination by flame atomic absorption spectrometry. The method is based on complex formation on the surface of the ENVI-18 DISKTM disks modified carbonyl and carboxyl functionalized-nano graphene oxide molecules covalently bonded together followed by stripping of the retained species by minimum amounts of appropriate organic solvents. The elution is efficient and quantitative. The effect of potential interfering ions, pH, SPFNano graphene, amount, stripping solvent, and sample flow rate were also investigated. Under the optimal experimental conditions, the break-through volume was found to about 1000mL providing a preconcentration factor of 500. The maximum capacity of the disks was found to be 456± 3 µg for Zn2+.The limit of detection of the proposed method is 5ng per 1000mL.The method was applied to the extraction and recovery of Zn in different water samples.
      کلید واژگان
      Zn(II)
      SPE
      Octadecyl slica disks
      FAAS
      carbonyl and carboxyl functionalized-nano grapheme (SPFNano graphene)

      شماره نشریه
      4
      تاریخ نشر
      2012-12-01
      1391-09-11
      ناشر
      Islamic Azad University, Damghan Branch, Islamic Republic of Iran

      شاپا
      2251-6719
      2251-6727
      URI
      https://dx.doi.org/10.22034/jchr.2018.544012
      http://www.jchr.org/article_544012.html
      https://iranjournals.nlai.ir/handle/123456789/69772