Determination of Trace Amounts of Gold in Environmental Samples by Adsorptive Stripping Voltammetry of Its Complex with Rhodamine Using Osc-Pls
(ندگان)پدیدآور
Akrami, A.Niazi, A.Bagheban-Shahri, F.نوع مدرک
Textزبان مدرک
Englishچکیده
The multivariate calibration method was applied for the determination of trace amounts of gold based on a hanging mercury drop electrode (HMDE) in the presence of rhodanine, followed by reduction of adsorbed gold by voltammetric scan using differential pulse modulation The optimum experimental conditions are: rhodanine concentration of 0.20 mg mL-1, pH 5.0, accumulation potential of -600 mV versus Ag/AgCl, accumulation time of 100 sec, scan rate of 30 mV s-1 and pulse height of 100 mV. The calibration matrix for partial least squares (PLS) regression was designed with 9 samples. Orthogonal signal correction (OSC) is a preprocessing technique used for removing the information unrelated to the target variables based on constrained principal component analysis. OSC is a suitable preprocessing method for PLS calibration without loss of prediction capacity using electrochemical method. The RMSEP for gold determination with PLS and OSC-PLS were 8.51 and 1.94, respectively. This procedure allows the determination of gold in synthetic and real samples with good reliability of the determination.Â
کلید واژگان
goldDetermination
Stripping
Voltammetric
PLS
OSC
شماره نشریه
3تاریخ نشر
2012-09-011391-06-11
ناشر
Islamic Azad University, Damghan Branch, Islamic Republic of Iranشاپا
2251-67192251-6727