• ورود به سامانه
      مشاهده مورد 
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Journal of Chemical Health Risks
      • Volume 7, Issue 1
      • مشاهده مورد
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Journal of Chemical Health Risks
      • Volume 7, Issue 1
      • مشاهده مورد
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      Selective Dispersive Solid Phase Extraction of Ser-traline Using Surface Molecularly Imprinted Polymer Grafted on SiO2/Graphene Oxide

      (ندگان)پدیدآور
      Khalilian, FaezehKhajoie Kermani, Feloria
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      810.6کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      A surface molecularly imprinted dispersive solid phase extraction coupled with liquid chromatography–ultraviolet detection is proposed as a selective and fast clean-up technique for the determination of sertraline in biological sample. Surface sertraline-molecular imprinted polymer was grafted and synthesized on the SiO2/graphene oxide surface. Firstly SiO2 was coated on synthesized graphene oxide sheet using sol-gel technique. Prior to polymerization, the vinyl group was incorporated on to the surface of SiO2/graphene oxide to direct selective polymerization on the surface. Methacrylic acid, ethylene glycol dimethacrylate and ethanol were used as monomer, cross-linker and progen, respectively. Non-imprinted polymer was also prepared for comparing purposes. The properties of the molecular imprinted polymer were characterized using field emission-scanning electron microscopy and Fourier transform infrared spectroscopy methods. The surface molecular imprinted polymer was utilized as an adsorbent of dispersive solid phase extraction for separation and preconcentration of sertraline. The effects of the different parameters influencing the extraction efficiency, such as sample pH were investigated and optimized. The specificity of the molecular imprinted polymer over the non-imprinted polymer was examined in absence and presence of competitive drugs. Sertraline calibration curve showed linearity in the ranges 1–500 µg L-1. The limits of detection and quantification under optimized conditions were obtained 0.2 and 0.5 µg L-1. The within-day and between-day relative standard deviations (n=3) were 4.3 and 7.1%, respectively. Furthermore, the relative recoveries for spiked biological samples were above 92%.
      کلید واژگان
      Biological liquids analysis
      Sertraline
      Dispersive solid phase extraction
      SiO2/graphene oxide
      Surface molecular imprinted polymer

      شماره نشریه
      1
      تاریخ نشر
      2017-01-01
      1395-10-12
      ناشر
      Islamic Azad University, Damghan Branch, Islamic Republic of Iran
      سازمان پدید آورنده
      Department of Chemistry, College of Basic Science, Yadegar -e-Imam Khomeini (RAH) Shahre Rey Branch, Islamic Azad University, Tehran, Iran
      Department of Chemistry, College of Basic Science, Yadegar -e-Imam Khomeini (RAH) Shahre Rey Branch, Islamic Azad University, Tehran, Iran

      شاپا
      2251-6719
      2251-6727
      URI
      https://dx.doi.org/10.22034/jchr.2017.544164
      http://www.jchr.org/article_544164.html
      https://iranjournals.nlai.ir/handle/123456789/69663

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب