      Investigation of the dose enhancement effect of spherical bismuth oxide nanoparticles in external beam radiotherapy

      (ندگان)پدیدآور
      Alyani Nezhad, ZahraGeraily, GhazaleHataminia, FatemehGholami, SomayehAbtahi, Seyed Mohammad MahdiGhanbari, Hossien
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      1.112 مگابایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Research Article
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Introduction: External radiotherapy is the most common method of radiotherapy which the most important problem associated with is that there is no difference between healthy and tumor tissues in dose absorption. One way to differentiate the dose sensitivity is to use metal-based nanoparticles. Bismuth oxide nanoparticles are good candidates for cancer radiotherapy. In this study, we investigated the dose enhancement effect of the synthesized spherical Bi2O3 NPs in 6MV external radiotherapy. Material and methods: Bi2O3 were synthesized and GENIPIN gel dosimeter was produced and divided into two equal portions, one part to fill vials containing pure gel and the other part to be added to a specified amount of nanoparticles to give a concentration of 0.1Mm. Then, the irradiation of the pure gel and gel vials containing the NPs was performed one day after manufacture by a 6MV external radiotherapy device. Gel readout was performed using spectrophotometer and absorption-dose curves were achieved. Results: results show that spherical Bi2O3 NPs cause a decrease in GENIPIN absorbance range compared to gel without NPs. The slope of the absorbance-dose curve in presence of NPs is 0.038 which is more than this slop in the pure gel (0.029) which indicates a DEF of 1.31 in the usage of these NPs in the tumor. Conclusion: we can conclude that by applying these spherical Bi2O3 NPs, dose absorption of the tumor will increase up to 31% which means the efficacy of radiotherapy can be maintained by lower applied dose to the tumor and healthy cells.
      کلید واژگان
      External radiotherapy
      bismuth oxide
      nanoparticles
      dose enhancement
      gel dosimetry
      GENIPIN gel

      شماره نشریه
      1
      تاریخ نشر
      2020-03-01
      1398-12-11
      ناشر
      Iranian Society of Nanomedicine
      سازمان پدید آورنده
      Department of Medical Physics and Medical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran
      Department of Medical Physics and Medical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran
      Department of Medical Nanotechnology, School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran, Iran
      Radiotherapy Oncology and radiobiology Research Centre, Cancer Institute, Tehran University of Medical Sciences, Tehran, Iran
      Department of Physics, Imam Khomeini International University, Qazvin, Iran
      Department of Medical Nanotechnology, School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran, Iran

      شاپا
      2476-3489
      2476-7123
      URI
      https://dx.doi.org/10.22034/nmrj.2020.01.007
      http://www.nanomedicine-rj.com/article_38646.html
      https://iranjournals.nlai.ir/handle/123456789/59697

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب