• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Nanomedicine Research Journal
    • Volume 5, Issue 1
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Nanomedicine Research Journal
    • Volume 5, Issue 1
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Au nanorods/ g-C3N4 composite based biosensor for electrochemical detection of chronic lymphocytic leukemia

    (ندگان)پدیدآور
    Afzali, MohadesehMohammad Shafiee, Mohammad RezaParhizkar, Janan
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.087 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Research Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Objective: With the increasing incidence of cancer and the dramatic effect of early detection on treatment and increase patient's life, many efforts have been devoted to making sensitive diagnosis systems. DNA as a biomarker for diagnosis of different types of cancers at the early stages of illness has attracted much attention.Methods: In this research novel electrochemical biosensor was developed using Pb2+ modified titanium phosphate nanoparticles and two DNA as capture probes. Considerable amounts of lead ions were mounted on the surface of titanium phosphate which produced the electrochemical signal. The surface of the biosensor electrode was modified by Au nanorods/ g-C3N4 composite. The functional group on the surface of g-C3N4, the chemical composition of tip, the morphology of composite and elemental composition of the composite were investigated by Fourier Transform Infrared Spectroscopy (FTIR), X-Ray Diffraction (XRD), Field Emission Scanning Electron Microscope (FESEM), Energy Dispersive X-Ray Spectroscopy (EDS), respectively.Results: The peaks of C, N, and Au were observed in the EDS spectrum. The presence of Au peaks in the EDS spectrum confirmed the formation of composite from Au nanorods and g-C3N4 sheets. Whit this biosensor the linear range from 0.6 nM to 6.4 nM and the detection limit of 20 PM for target DNA was obtained.Conclusion: Finally, it seems that the glassy carbon electrode modified with Au-nanorods/g-C3N4 composite is a good candidate for cancer diagnosis in the early stages.
    کلید واژگان
    Chronic lymphocytic leukemia
    DNA biosensor
    gold nanorod
    square wave voltammetry
    g-C3N4

    شماره نشریه
    1
    تاریخ نشر
    2020-03-01
    1398-12-11
    ناشر
    Iranian Society of Nanomedicine
    سازمان پدید آورنده
    Department of chemistry Faculty of Sciences, Islamic Azad University, Najafabad Branch, Najafabad, Iran.
    Department of chemistry Faculty of Sciences, Islamic Azad University, Najafabad Branch, Najafabad, Iran.
    Nanotechnology Laboratory, Department of Chemistry, University of Isfahan, Isfahan, Iran.

    شاپا
    2476-3489
    2476-7123
    URI
    https://dx.doi.org/10.22034/nmrj.2020.01.005
    http://www.nanomedicine-rj.com/article_38644.html
    https://iranjournals.nlai.ir/handle/123456789/59695

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب