      Pillow-Shape Base Isolation System and Its Seismic Behavior

      (ندگان)پدیدآور
      Tayaran, AliHosseini, Mahmood
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      1.363 مگابایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      In this paper a new isolating system is introduced for short to mid-rise buildings. In comparison to conventional systems such as LRB and HRB, the proposed system has the advantage of no need to cutting edge technology and has low manufacturing cost. This system is made up of two orthogonal pairs of pillow-shaped rollers that are located between flat bed and plates. By using this system in two perpendicular directions, building can move in all horizontal directions with respect to its foundation. Due to the pillow shape of the roller, this system has self-centering capability which causes it to return to its original position after the earthquake. The rolling friction force between pillows and their bed creates some damping in the system which prevents it from further oscillation after earthquake excitations diminish. The purpose of this study is to evaluate the proposed isolation system's performance under different earthquake excitations. First of all general features of the proposed isolators have been introduced followed by the analytical equations of the system. Vertical bearing capacity and the effects of the thickness of pillows has been investigated using ABAQUS software. It has been shown that for a pair of pillows of 58 cm width, 45 cm height and 100 cm length the vertical load bearing capacity of the system is more than 300 tons. The period of system with respect to the height and radius of curvature of the rollers, and seismic response of a building, assumed as a rigid body resting on isolators, has been studied subjected to simultaneous effects of horizontal and vertical excitations. It has been shown that the proposed system can reduce the absolute acceleration in the building around 78% in average, while the building's maximum displacement is around 1.77 times of the ground in average.
      کلید واژگان
      Rolling Isolation
      Lagrange Equation
      Runge-Kutta Technique
      Finite element analysis

      شماره نشریه
      2
      تاریخ نشر
      2015-05-01
      1394-02-11
      ناشر
      Civil Engineering & Construction Research Center (CCRC), QIAU
      سازمان پدید آورنده
      Graduate Student, Department of Civil, South Tehran Branch, Islamic Azad University, Tehran, Iran.
      Associate Professor, Department of Civil, South Tehran Branch, Islamic Azad University, Tehran, Iran

      شاپا
      2476-5465
      URI
      http://www.qjseg.ir/article_750.html
      https://iranjournals.nlai.ir/handle/123456789/46477

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب