    JavaScript is disabled for your browser. Some features of this site may not work without it.

    New Modeling of Metal Oxide Surge Arresters

    (ندگان)پدیدآور
    Hosseini, SeyedMohammad HassanGharadaghi, Yoones
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.262 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    This paper describes simplified modeling of metal oxide surge arrester (MOSA) to operate analysis. This model is a new model proposed (P-K Model) to verify the accuracy in order to compare with IEEE and Pinceti Model. The simulations are performed with the Alternative Transients Program version of Electromagnetic Transient Program (ATP-EMTP). In the present paper, the MOSA models were verified for several medium voltages which consist of 18 kV and 21 kV, which 18 kV arrester was used in 22 kV system of Provincial Electricity Authority (PEA) and 21 kV arrester was used in 24 kV system of Metropolitan Electricity Authority (MEA) in Thailand. The P-K model was evaluate from different manufacturing, it is based on the General Electric (GE), Siemens and Ohio Brass as well as IEEE and Pinceti Model. The tests are performed by applying a fast front current surge with front time of up to 0.5μs and the standard impulse current surge (8/20μs). The results were compared between three models in order to calculate the error operation of the MOSA in the ATP-EMTP Program. The relative error of arrester models show that the P-K model can be used to simulate and calculate in ATP-EMTP program as well as IEEE and Pinceti model. In the case of fast front current surge, the P-K model has a maximum error of 5.39% (Ohio Brass, 10 kA, 21 kV) and has a minimum error of 0.24% (GE, 10 kA, 18 kV). Also, the standard impulse current surge, P-K model has a maximum error of 2% (Ohio Brass, 10 kA, 18 kV) and has a minimum error of 0.32% (Siemens, 10 kA, 21 kV) in the voltage response.

    شماره نشریه
    3
    تاریخ نشر
    2017-09-01
    1396-06-10
    ناشر
    Islamic Azad University, South Tehran Branch
    سازمان پدید آورنده
    Electrical Engineering Department South Tehran Branch, Islamic Azad University Tehran, Iran
    Electrical Engineering Department South Tehran Branch, Islamic Azad University Tehran, Iran

    شاپا
    2588-7327
    2588-7335
    URI
    http://spre.azad.ac.ir/article_535278.html
    https://iranjournals.nlai.ir/handle/123456789/45883

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب