• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Medical Sciences
    • Volume 40, Issue 5
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Medical Sciences
    • Volume 40, Issue 5
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs

    (ندگان)پدیدآور
    Shahcheraghi, Gholam HosseinHashemi, Seyed Ali
    Thumbnail
    نوع مدرک
    Text
    Original Article(s)
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in 42 patients with the mean age of 48.8 years were retrospectively studied. Two groups of prosthesis had been implanted: Harris-Galante II (HGII) in 15 and Versys-Trilogy (V-T) in 37 hips, both from Zimmer company. The patients were assessed clinically, radiographically and with Harris hip score, SF36, WOMAC, and MACTAR questionnaires, with 65 months (26-136) mean follow-up.Results: All the V-T prostheses had survived well. Eight of HG II were revised by the last follow-up in 19-102 months. All had undergone acetabular revision and 2 combined with femoral revision. Broken tines of HGII cups were seen in 4 radiographs. The 65 months overall survival was 96.2% for femoral and 84.6% for acetabular components. 90% had good or excellent Harris hip scores. The functional scores were poorer in the HG II group. Pain relief and improved walking were the two main patients' expectations fulfilled in 97.6% and 92.8%, respectively.Conclusions: The outcome of cementless total hip arthroplasty (THA) is satisfactory and comparable with the literature based on the results of function and survival of this small comparative group. The use of HGII acetabular component should be abandoned.
    کلید واژگان
    Hip arthroplasty replacement
    Porous-coated
    Outcome
    Hip Prosthesis

    شماره نشریه
    5
    تاریخ نشر
    2015-09-01
    1394-06-10
    ناشر
    Shiraz University of Medical Sciences
    سازمان پدید آورنده
    Professor of Orthopaedic Surgery, Bone and Joint Disease Research Center, Department of Orthopedic Surgery, Nemazee Hospital, Shiraz University of Medical Sciences, Shiraz, Iran
    Assistant professor of Orthopaedic Surgery, Bone and Joint Disease Research Center, Department of Orthopedic Surgery, Nemazee Hospital, Shiraz University of Medical Sciences, Shiraz, Iran

    شاپا
    0253-0716
    1735-3688
    URI
    https://ijms.sums.ac.ir/article_39995.html
    https://iranjournals.nlai.ir/handle/123456789/440039

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب