• ورود به سامانه
      مشاهده مورد 
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Journal of Electrical and Computer Engineering Innovations (JECEI)
      • Volume 8, Issue 1
      • مشاهده مورد
      •   صفحهٔ اصلی
      • نشریات انگلیسی
      • Journal of Electrical and Computer Engineering Innovations (JECEI)
      • Volume 8, Issue 1
      • مشاهده مورد
      JavaScript is disabled for your browser. Some features of this site may not work without it.

      Utilization of CHB Multilevel Inverter for Harmonic Reduction in Fuzzy Logic Controlled Multiphase LIM Drives

      (ندگان)پدیدآور
      Hamedani, P.Shoulaei, A.
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      1.390 مگابایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Research Paper
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Background and Objectives: Despite superior privileges that multiphase motors offer in comparison with their three-phase counterparts, in the field of multiphase linear induction motors (LIMs) few studies have been reported until now. To combine the advantages of both multiphase motors and linear induction motors, this paper concentrates on multiphase LIM drives considering the end effects. Methods: The main contributions of this paper can be divided into two major categories. First, a comparative study has been conducted about the dynamic performance of Fuzzy Logic Controller (FLC) and Genetic-PI controller for a seven-phase LIM drive; and second, because of the superior performance of the FLC method revealed from the results, the harmonic pollution of the FLC based LIM drive has been studied in the case of supplying through a five-level Cascaded H-bridge (CHB) VSI and then compared with the traditional two-level VSI fed one. Results: The five-level CHB-VSI has utilized a multiband hysteresis modulation scheme and the two-level VSI has used the traditional three-level hysteresis modulation strategy. Note that for harmonic distortion assessment both harmonic and interharmonic components are considered in THD calculations. Conclusion: The results validate the effectiveness of the proposed FLC for seven-phase LIM drive supplied with five-level CHB-VSI and guarantee for perfect control characteristics, lower maximum starting current, and significant harmonic and interharmonic reduction.
      کلید واژگان
      CHB Inverter
      Fuzzy logic controller
      Linear Induction Motor (LIM)
      Multiphase LIM
      Total Harmonic Distortion
      Power Electronic

      شماره نشریه
      1
      تاریخ نشر
      2020-01-01
      1398-10-11
      ناشر
      Shahid Rajaee Teacher Training University
      سازمان پدید آورنده
      Department of Railway Engineering and Transportation Planning, University of Isfahan, Isfahan, Iran
      Department of Electrical Engineering, Iran University of Science & Technology, Tehran, Iran.

      شاپا
      2322-3952
      2345-3044
      URI
      https://dx.doi.org/10.22061/jecei.2020.6664.355
      http://jecei.sru.ac.ir/article_1420.html
      https://iranjournals.nlai.ir/handle/123456789/437511

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب