• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Journal of Biomedical Physics and Engineering
    • Volume 10, Issue 5
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Journal of Biomedical Physics and Engineering
    • Volume 10, Issue 5
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Bio-Numerical Analysis of the Human Ankle-Foot Model Corresponding to Neutral Standing Condition

    (ندگان)پدیدآور
    Darwich, ANazha, HNazha, ADaoud, MAlhussein, A
    Thumbnail
    نوع مدرک
    Text
    Original Research
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Background: The foot is the most complex body's structure; it is highly susceptible to disorders because of its loading pattern. The complexity of the foot structure geometry implies the use of reverse engineering tools to obtain a model that can accurately mimic the biomechanical behavior of the foot. Objective: The objective of this study is to establish a state-of-the-art ankle-foot finite element (FE) model with anatomically realistic geometry and structure in order to get the model that will suit all cases for future studies on stress injuries and foot insole designs under different loading conditions.Material and Methods: In this analytical study, tomography images were imported in DICOM format, after that, the object was exported in the form of three-dimensional structures in STL file format to define and assemble the structures. After that, the computer simulation on numerical model was done. One-way Analysis of variance (ANOVA) test was performed, and a threshold (pResults: The results showed no significant differences (P>0.05) between the values of the plantar pressure corresponding to neutral standing condition with other foot models in literature. The stresses transferred to the bone structure show that the relatively higher stress was located in the fifth, fourth and third tarsometatarsal, where the maximum von Mises stress in the bone structure was 2155.4 kPa. 0.05) between the values of the plantar pressure corresponding to neutral standing condition with other foot models in literature. The stresses transferred to the bone structure show that the relatively higher stress was located in the fifth, fourth and third tarsometatarsal, where the maximum von Mises stress in the bone structure was 2155.4 kPa. Conclusion: The state-of-the-art ankle-foot FE model with anatomically realistic geometry and structure will be very helpful for future studies on stress injuries and foot insole designs under different loading conditions.
    کلید واژگان
    Methods
    Ankle
    Foot
    Stress Distribution
    Neutral Standing

    شماره نشریه
    5
    تاریخ نشر
    2020-10-01
    1399-07-10
    ناشر
    Shiraz University of Medical Sciences
    سازمان پدید آورنده
    PhD, Faculty of Biomedical Engineering, Al-Andalus University for Medical Sciences, Tartous, Syria
    PhD, Faculty of Technical Engineering, University of Tartous, Tartous, Syria
    BSc, Faculty of Mechanical and Electrical Engineering, Damascus University, Damascus, Syria
    PhD, Technological Research Institute Materials, Metallurgy and Processes, Metz, France
    PhD, ICD-LASMIS, University of Technology of Troyes, Nogent, France

    شاپا
    2251-7200
    URI
    https://dx.doi.org/10.31661/jbpe.v0i0.2004-1094
    https://jbpe.sums.ac.ir/article_46915.html
    https://iranjournals.nlai.ir/handle/123456789/434714

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب