    Comparison of Asymmetric Reaming versus a Posteriorly Augmented Component for Posterior Glenoid Wear and Retroversion: A Radiographic Study

    (ندگان)پدیدآور
    Kevin Ko, Jia-WeiSyed, Usman AliBarlow, Jonathan D.Paxton, ScottLoeffler, Bryan J.Thakar, OceanJamgochian, GrantAbboud, JosephGetz, Charles L.Williams, Gerald R.
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    949.7کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    RESEARCH PAPER
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Background: Managing posterior glenoid wear and retroversion remains a challenge in shoulder arthroplasty.Correcting glenoid version through asymmetric reaming (AR) with placement of a standard glenoid component and theuse of posteriorly augmented glenoid (PAG) components are two methods used to address this problem. Our objectiveis to report the radiographic outcomes of patients with posterior glenoid wear and/or retroversion treated with eitherapproach.Methods: Patients with posterior glenoid wear and a minimum of 15 degrees of retroversion, treated with AR andstandard glenoid component or with a PAG component (3 mm, 5 mm, or 7 mm posterior augmentation), wereconsecutively identified through retrospective chart review. Pre-operative axillary views were evaluated for version,humeral head subluxation in relation to scapular axis and to mid-glenoid face. Post-operative axillary views werereviewed to measure corrected inversion and humeral head subluxation.Results: There were 48 patients in the AR group and 49 patients in the PAG group. Version improved 6.8 degrees in theAR group. In the PAG group, version improved 8.8 degrees with 3 mm augment, 13.4 degrees with 5 mm augment, and12.8 with 7 mm augments. There were significantly more central peg perforations in the 5 mm PAG group comparedto other groups. The humeral head was re-centered within 6.1% of normal in all groups except 7 mm augments.Conclusion: This study demonstrates that AR and PAGs have the ability to re-center the humeral head when utilizedin patients with retroversion and posterior wear. Use of a PAG component may allow for greater correction of glenoidretroversion, however, there is an increased risk for central peg perforation with the specific implant utilized in this study.Long-term follow-up is ongoing and needed to understand the clinical implications of these findings.Level of evidence: IV
    کلید واژگان
    Augmented Glenoid
    Glenoid Reaming
    Shoulder Arthritis
    Total Shoulder Arthoplasty
    Shoulder

    شماره نشریه
    4
    تاریخ نشر
    2019-07-01
    1398-04-10
    ناشر
    Mashhad University of Medical Sciences, Iranian Society of Knee Surgery, Arthroscopy and Sports Tramatology,Iranian Orthopaedic Association
    سازمان پدید آورنده
    Orthopedic Physician Associates at Swedish Orthopedic Insitiute, Seattle, WA, USA
    The Rothman Institute at Thomas Jefferson University, Philadelphia, PA, USA
    Ohio State University, Wexner Medical Center, Columbus, OH, USA
    Brown University, Providence, RI, USA
    OrthoCarolina, Charlotte, NC, USA
    The Rothman Institute at Thomas Jefferson University, Philadelphia, PA, USA
    The Rothman Institute at Thomas Jefferson University, Philadelphia, PA, USA
    The Rothman Institute at Thomas Jefferson University, Philadelphia, PA, USA
    The Rothman Institute at Thomas Jefferson University, Philadelphia, PA, USA
    The Rothman Institute at Thomas Jefferson University, Philadelphia, PA, USA

    شاپا
    2345-4644
    2345-461X
    URI
    https://dx.doi.org/10.22038/abjs.2019.28430.1751
    http://abjs.mums.ac.ir/article_12916.html
    https://iranjournals.nlai.ir/handle/123456789/431887

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب