• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • The Archives of Bone and Joint Surgery
    • Volume 5, Issue 3
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • The Archives of Bone and Joint Surgery
    • Volume 5, Issue 3
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Comparison of Double and Single Leg Weight-Bearing Radiography in Determining Knee Alignment

    (ندگان)پدیدآور
    Yazdanpanah, OmidKarimi Mobarakeh, MahmoudNakhaei, MasoudBaneshi, Mohammad R.
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    630.5کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    RESEARCH PAPER
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Background: Knee malalignment is an important modifiable cause of osteoarthritis (OA). Surgical therapeutic procedures depend on proper knee alignment assessment. The purpose of this study was to compare knee alignment parameters between double and single leg weight-bearing radiographs and to evaluate the reproducibility of inter- and intra-observer measurements. Methods: One hundred eight patients (59 male and 49 female) with knee deformity visited at Kerman Knee Clinic were selected. Full limb anteroposterior (AP) Radiographs were taken for each participant in double and single leg weight-bearing positions. Hip-Knee-Ankle Angle (HKAA), Medial-Proximal-Tibial Angle (MPTA), Lateral-Distal-Femoral Angle (LDFA) and Joint-Line-Convergence Angle (JLCA) measured. Images stored on PC were examined by three observers to assess inter and intra observer reproducibility. Data analysis was done by SPSS software. Results: The mean age of patients was 48.4 (±6.84) years, mean BMI was 26.55 (±1.94) Kg/m2. The mean HKAA and JLCA were significantly different between double and single leg weight-bearing radiographs. Intraclass correlation coefficient (ICC) test showed high (0.99) inter-reproducibility between three observers in all cases, except one (ICC=0.92). Intra-observer reproducibility indicated a strong correlation between the observer's measurements at different times (ICC > 0.99). 0.99). Conclusion: HKAA and JLCA were affected by the patient's position. Observer and time interval had no effect on either of HKAA, MPTA, LDFA, and JLCA. Also the measurement of knee alignment parameters was not dependent on observer's experience. In conclusion single leg weight-bearing radiography is more representative of knee alignment and is inter and intra-observer reproducible.
    کلید واژگان
    Knee alignment
    Osteoarthritis
    Radiography
    Reliability
    Knee

    شماره نشریه
    3
    تاریخ نشر
    2017-05-01
    1396-02-11
    ناشر
    Mashhad University of Medical Sciences, Iranian Society of Knee Surgery, Arthroscopy and Sports Tramatology,Iranian Orthopaedic Association
    سازمان پدید آورنده
    Kerman University of Medical Sciences, Kerman, Iran
    Department of Orthopedics, Kerman University of Medical Sciences, Kerman, Iran
    Kerman University of Medical Sciences, Kerman, Iran
    Research Center for Modeling in Health, Institute for Futures Studies in Health, Kerman University of Medical Sciences, Kerman, Iran

    شاپا
    2345-4644
    2345-461X
    URI
    https://dx.doi.org/10.22038/abjs.2017.20780.1538
    http://abjs.mums.ac.ir/article_8566.html
    https://iranjournals.nlai.ir/handle/123456789/431713

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب