      Investigations on Surface Integrity and Electrochemical Behavior of Machined Co-Cr-Mo Bio-implant Alloy

      (ندگان)پدیدآور
      Jagtap, K. A.Pawade, R. S.Giradkar, K. V.
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      618.8کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Article
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      A decisive constraint for the long-term stability of the artificial joint is to minimize the release of debris particles. The wear/debris induced osteolysis and aseptic loosening are the result of failure of metal-on-metal joint implants. SPD processes have been used to adapt the surface integrity properties by generating ultrafine or even nano-sized grains and grain size gradients in the surface region of work materials. These fine grained materials often show enhanced surface integrity properties and improved functional performance (wear resistance, corrosion resistance, fatigue life, etc.) compared with their predictable coarse grained counterparts. To identify the implant material's post machined behaviour in biological environment, the experiments were planned by precision CNC turning process and accordingly post machined surfaces were analyzed by contact type and electrochemical measurement processes. The work includes effect of machining parameters on machined surface roughness and corrosion rate by an electrochemistry of Co-Cr-Mo bio-implant alloy. The minimum machined surface roughness value 0.450 µm shows minimum corrosion rate as 0.00002 mm/year. It is also shown that feed rate is having predominating effect on machined surface roughness and rake angle is on corrosion rate of Co-Cr-Mo bio-implant alloy.
      کلید واژگان
      6 August 2016
      Revised: 15 October 2016
      Accepted: 3 November 2016

      شماره نشریه
      4
      تاریخ نشر
      2016-12-01
      1395-09-11
      ناشر
      Islamic Azad University Majlesi Branch
      سازمان پدید آورنده
      Research Scholar, Department of Mechanical Engineering, Dr. Babasaheb Ambedkar Technological University, Lonere, Raigad, MS, India
      Associate Professor, Department of Mechanical Engineering, Dr. Babasaheb Ambedkar Technological University, Lonere, Raigad, MS, India
      PG Student, Department of Mechanical Engineering, Dr. Babasaheb Ambedkar Technological University, Lonere, Raigad, MS, India

      شاپا
      2252-0406
      2383-4447
      URI
      http://admt.iaumajlesi.ac.ir/article_534991.html
      https://iranjournals.nlai.ir/handle/123456789/428992

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب