CASE REPORT: SUCTION TIP MIGRATION TO INTERNAL ILIAC VEIN DURING CARDIAC SURGERY
(ندگان)پدیدآور
MASOUMI, M.A.SABZI, F.
نوع مدرک
Textزبان مدرک
Englishچکیده
Journal: IRANIAN HEART JOURNAL (IHJ) FALL 2009 , Volume 10 , Number 3; Page(s) 44 To 46.
Paper: CASE REPORT: SUCTION TIP MIGRATION TO INTERNAL ILIAC VEIN DURING CARDIAC SURGERY
Author(s): MASOUMI M.A.*, SABZI F.
* DEPT. OF CARDIAC SURGERY, IMAM ALI (A. S.) MEDICAL CENTER, KERMANSHAH UNIVERSITY OF MEDICAL SCIENCES, KERMANSHAH, IRAN
Abstract:
During the cannulation of the inferior vena cava in a 29-year-old patient undergoing mitral and aortic valve replacement, the pump suction tip was inadvertently lost in the right atrium. After starting CPB and cardioplegic arrest of the heart, the right atrium and ventricle were searched for the foreign body, but it became evident by reontgenography that the foreign body had migrated to the pelvic veins. At the end of the operation, extraction with a Fogarty catheter was attempted but was not successful and the foreign body was extracted via laparatomy.
کلید واژگان
FOREIGN BODY MIGRATIONILIAC VEIN
Heart Surgery
شماره نشریه
3تاریخ نشر
2009-09-011388-06-10