      Diagnostic Accuracy of Positron Emission Mammography with 18F-fluorodeoxyglucose in Breast Cancer Tumor of Less than 20 mm in Size

      (ندگان)پدیدآور
      Yano, FuzukiItoh, MasatoshiHirakawa, HisashiYamamoto, SeiichiYoshikawa, AkiraHatazawa, Jun
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      1007.کیلوبایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      Original Article
      زبان مدرک
      English
      نمایش کامل رکورد
      چکیده
      Objective(s): To investigate the diagnostic accuracy of positron emission mammography (PEM) and positron emission tomography/computed tomography (PET/CT) for small breast tumors of less than 20 mm in size.Methods: The study was conducted on a total of 100 subjects (i.e., 50 patients with pathologically proven breast cancer and 50 normal cases of medical screening). The total number of tumors was 54 (mean size: 11±5.1 mm, range:4-20 mm). The diagnostic accuracy of PEM alone, PET/CT alone, and combined PET/CT and PEM was evaluated by two nuclear medicine physicians based on visual inspection. The two groups (i.e., tumors of ≤ 10 mm and > 10-20 mm) were 10-20 mm) werecompared in terms of the diagnostic capability of the three modalities (PEM alone, PET/CT alone, and PET/CT+PEM).Results: The sensitivities of PEM alone, PET/CT alone, and combined PET/CT and PEM were 72%, 60%, and 76%, respectively. The specificities of these tests were 98%, 100%, and 98%, respectively. Furthermore, the accuracies of these diagnostic modalities were 85%, 79%, and 87%, respectively. The combined PET/CT and PEM showed significantly higher sensitivity and accuracy than PET/CT alone (P=0.005 and P=0.02, respectively). In addition, PEM demonstrated asignificantly higher sensitivity than PET/CT in the ≤ 10 mm group (P=0.03); however, no difference was observed between the two modalities in the > 10 mm group in terms of sensitivity. 10 mm group in terms of sensitivity.Conclusion: 18F-fluorodeoxyglucose PET had limited capability for the detection of small breast cancers of
      کلید واژگان
      positron emission mammography
      PEM
      PET/CT
      Breast Cancer
      diagnostic accuracy
      Oncology

      شماره نشریه
      1
      تاریخ نشر
      2019-01-01
      1397-10-11
      ناشر
      Asia Oceania Federation of Nuclear Medicine & Biology
      سازمان پدید آورنده
      Department of Nuclear Medicine and Tracer Kinetics, Osaka University Graduate School of Medicine
      Sendai Medical Imaging Clinic (Gazo Kenshin)
      Department of Breast Surgery, Tohoku Kosai Hospital
      Department of Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine, Nagoya, Japan
      Institute for Materials Research, Tohoku University
      Osaka University Graduate School of Medicine

      شاپا
      2322-5718
      2322-5726
      URI
      https://dx.doi.org/10.22038/aojnmb.2018.31101.1213
      http://aojnmb.mums.ac.ir/article_11443.html
      https://iranjournals.nlai.ir/handle/123456789/420908

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب