      Porosity Rendering in High-Performance Architecture: Wind-Driven Natural Ventilation and Porosity Distribution Patterns

      (ندگان)پدیدآور
      Saadatjoo, PariaMahdavinejad, MohammadjavadZarkesh, Afsaneh
      Thumbnail
      دریافت مدرک مشاهده
      FullText
      اندازه فایل: 
      4.013 مگابایت
      نوع فايل (MIME): 
      PDF
      نوع مدرک
      Text
      مقاله پژوهشی
      زبان مدرک
      فارسی
      نمایش کامل رکورد
      چکیده
      Natural ventilation is one of the most essential issues in the concept of high-performance architecture. The porosity has a lot to do with wind-phil architecture to meet high efficiency in integrated architectural design and materialization a high-performance building. Natural ventilation performance in porous buildings is influenced by a wide range of interrelated factors including terrace depth, porosity distribution pattern, porosity ratio, continuity or interruption of the voids and, etc. The main objective of this paper is to investigate the effect of porosity distribution pattern on natural ventilation performance in a mid-rise building. One solid block and six porous residential models based on unit, row and combined relocation modules with different terrace depths (TD = 1.2, 1.5 m) were analyzed by computational fluid dynamics (CFD). The evaluations are based on grid sensitivity analysis and a validation of wind tunnel measurements. Investigations indicated that introducing the velocity into a solid block would enhance the building natural ventilation performance up to 64 percent compared to the solid case. However, it is demonstrated through simulations that the porosity distribution pattern as an architectural configuration has a significant effect on ventilation efficiency. Unit-Relocation models (U-RL) have approximately 1.64 times the mean airflow of the solid block, 1.1 times of Row-Relocation (R-RL) and 1.22 times of Combined-Relocation models (CO-RL). U-RL models are also able to achieve approximately 1.26 times the maximum air velocity inside the blocks compared to the solid case. This value is about 1.05 times of R-RL cases and 1.1 times of CO-RL cases. The results clearly indicated that porosity distribution pattern is a factor that could be modified by architects to fulfill most of architectural and environmental requirements.
      کلید واژگان
      Natural Ventilation
      High-performance Architecture
      Windphil Architecture
      porosity
      Distribution pattern

      شماره نشریه
      26
      تاریخ نشر
      2019-05-22
      1398-03-01
      ناشر
      دکتر مصطفی بهزادفر
      Dr. Mostafa Behzadfar
      سازمان پدید آورنده
      Assistant Professor of Architecture, Department of Architecture, University of Tabriz, Tabriz, Iran
      Associate Professor of Architecture, Department of Architecture, Tarbiat Modares University, Tehran, Iran
      Assistant Professor of Architecture, Department of Architecture, Tarbiat Modares University, Tehran, Iran

      شاپا
      2008-5079
      2538-2365
      URI
      https://dx.doi.org/10.22034/aaud.2019.89057
      http://www.armanshahrjournal.com/article_89057.html
      https://iranjournals.nlai.ir/handle/123456789/418093

      مرور

      همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

      حساب من

      ورود به سامانهثبت نام

      تازه ترین ها

      تازه ترین مدارک
      © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
      تماس با ما | ارسال بازخورد
      قدرت یافته توسطسیناوب